Compact portable sources of high-LET radiation: Validation and potential application for galactic cosmic radiation countermeasure discovery

Autor: Nolan E. Hertel, Steven R. Biegalski, Victoria I. Nelson, William A. Nelson, Sharmistha Mukhopadhyay, Zitong Su, Alexis M. Chan, Aparna H. Kesarwala, William S. Dynan
Rok vydání: 2022
Předmět:
Zdroj: Life Sciences in Space Research. 35:163-169
ISSN: 2214-5524
DOI: 10.1016/j.lssr.2022.10.002
Popis: Implementation of a systematic program for galactic cosmic radiation (GCR) countermeasure discovery will require convenient access to ground-based space radiation analogs. The current gold standard approach for GCR simulation is to use a particle accelerator for sequential irradiation with ion beams representing different GCR components. This has limitations, particularly for studies of non-acute responses, strategies that require robotic instrumentation, or implementation of complex in vitro models that are emerging as alternatives to animal experimentation. Here we explore theoretical and practical issues relating to a different approach to provide a high-LET radiation field for space radiation countermeasure discovery, based on use of compact portable sources to generate neutron-induced charged particles. We present modeling studies showing that DD and DT neutron generators, as well as an AmBe radionuclide-based source, generate charged particles with a linear energy transfer (LET) distribution that, within a range of biological interest extending from about 10 to 200 keV/μm, resembles the LET distribution of reference GCR radiation fields experienced in a spacecraft or on the lunar surface. We also demonstrate the feasibility of using DD neutrons to induce 53BP1 DNA double-strand break repair foci in the HBEC3-KT line of human bronchial epithelial cells, which are widely used for studies of lung carcinogenesis. The neutron-induced foci are larger and more persistent than X ray-induced foci, consistent with the induction of complex, difficult-to-repair DNA damage characteristic of exposure to high-LET (10 keV/μm) radiation. We discuss limitations of the neutron approach, including low fluence in the low LET range (10 keV/μm) and the absence of certain long-range features of high charge and energy particle tracks. We present a concept for integration of a compact portable source with a multiplex microfluidic in vitro culture system, and we discuss a pathway for further validation of the use of compact portable sources for countermeasure discovery.
Databáze: OpenAIRE