Corrosion of gold alloys and titanium in artificial saliva
Autor: | Dag Brune, Sigurd Melsom, Dag Magnar Evje |
---|---|
Rok vydání: | 1982 |
Předmět: |
Titanium
Time Factors Materials science Chemical Phenomena Chemistry Physical Metallurgy technology industry and agriculture chemistry.chemical_element Ionic bonding Particulates equipment and supplies Copper Corrosion Colloid Chemical state chemistry Phase (matter) Gold Alloys Radioactive Tracers Saliva General Dentistry Filtration |
Zdroj: | European Journal of Oral Sciences. 90:168-171 |
ISSN: | 1600-0722 0909-8836 |
DOI: | 10.1111/j.1600-0722.1982.tb01541.x |
Popis: | Two types of gold alloys and one type of pure titanium have been submitted to corrosion in artificial saliva for periods of up to about 2 months. The release of copper, gold or silver from the gold alloys as well as titanium from the titanium matrix was measured with nuclear tracer technique. The physical/chemical state of the corrosion products of gold alloys referring to the ionic state or presence in particulate form has been examined retaining the particulate matter on a glass filter. Copper was observed to be mainly present in the ionic state. Considerable amounts of gold were observed to be retained on the glass filter explained by the presence of gold in particular form or as a component of a dispersed colloidal phase. The estimation of the release of titanium was registered by the tracer nuclide 46Sc assuming particulate matter to be deteriorated from the titanium surface. |
Databáze: | OpenAIRE |
Externí odkaz: |