Percutaneous Treatment of Unprotected Left Main Disease With Thin-Strut Durable-Polymer or Early Generation Thicker-Strutted and Coated Bioabsorbable-Polymer Drug-Eluting Stents in a Large-Scale Registry
Autor: | Hyun Jae Kang, Jeehoon Kang, Bon Kwon Koo, Kyung Woo Park, Jung-Kyu Han, Hak Seung Lee, Hyo-Soo Kim, Haechan Cho, Michael S. Lee, Han Mo Yang |
---|---|
Rok vydání: | 2021 |
Předmět: |
Target lesion
medicine.medical_specialty Percutaneous Polymers medicine.medical_treatment Coronary Artery Disease 030204 cardiovascular system & hematology Prosthesis Design 03 medical and health sciences Percutaneous Coronary Intervention 0302 clinical medicine Absorbable Implants Humans Medicine Registries 030212 general & internal medicine Myocardial infarction Sirolimus business.industry Stent Percutaneous coronary intervention Drug-Eluting Stents General Medicine medicine.disease Surgery Treatment Outcome Drug-eluting stent Conventional PCI Cardiology and Cardiovascular Medicine business Kidney disease |
Zdroj: | Cardiovascular Revascularization Medicine. 32:43-49 |
ISSN: | 1553-8389 |
DOI: | 10.1016/j.carrev.2020.12.034 |
Popis: | Background The ideal drug-eluting stent (DES) for the treatment of unprotected left main coronary artery (ULMCA) is unknown. We compared percutaneous coronary intervention (PCI) using durable polymers versus early-generation, thicker strutted and coated bioabsorbable polymers for ULMCA disease. Methods Patients who underwent ULMCA PCI (893 patients) from April 2008 to November 2014 were identified from the Grand-DES registry. The primary end point was 3-year target lesion failure (TLF) after propensity score matching. Results The final analysis included 754 patients (84.4%) and 139 patients (15.6%) in the durable and bioabsorbable polymer group, respectively. The groups differed significantly in lesion and procedural characteristics. Propensity score-matched analysis revealed a trend toward a lower 3-year TLF in the durable polymer group (log rank p=0.071). Independent predictors of 3-year TLF were chronic kidney disease, presentation with acute myocardial infarction, and a two-stenting technique for ULMCA lesions. Definite/probable stent thrombosis rates at 3-years were low in both groups (0.8% vs. 0.7%, p=0.925). Conclusions The safety of ULCMA PCI was excellent, and durable and bioabsorbable polymer DES provided similar clinical outcomes at 3-year follow-up. Landmark analysis revealed that the durable polymer group had a lower TLF rate from 9 months. Further studies are needed to confirm these results. |
Databáze: | OpenAIRE |
Externí odkaz: |