Spontaneous long-term and urethane induced hippocampal EEG power, activity and temperature data from mice lacking the Cav3.2 voltage-gated Ca2+ channel
Autor: | Karl Broich, Magdalena Elisabeth Siwek, Jürgen Hescheler, Marco Weiergräber, Dan Ehninger, Anna Papazoglou, Christina Henseler, Johanna Daubner, Muhammad Imran Arshaad |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
Science (General)
Mouse Computer applications to medicine. Medical informatics R858-859.7 Alpha (ethology) Electroencephalography Hippocampal formation Hippocampus Urethane CA1 Q1-390 03 medical and health sciences 0302 clinical medicine Nuclear magnetic resonance ddc:570 medicine Hippocampus (mythology) Telemetry EEG Beta (finance) Data Article 030304 developmental biology 0303 health sciences Multidisciplinary medicine.diagnostic_test Voltage-gated ion channel Chemistry Activity Power Ca2 channels 030217 neurology & neurosurgery Hippocampal eeg |
Zdroj: | Data in Brief 36, 107027-(2021). doi:10.1016/j.dib.2021.107027 Data in Brief, Vol 36, Iss, Pp 107027-(2021) Data in Brief, 36:107027 Data in Brief |
DOI: | 10.1016/j.dib.2021.107027 |
Popis: | This article provides raw relative electroencephalographic (EEG) power, temperature and activity data from controls and Cav3.2 deficient mice. Radiotransmitter implantation was carried out in male experimental mice under ketamine/xylazine narcosis. Following a recovery period, radiotelemetric EEG recordings from the hippocampal CA1 region were obtained under spontaneous 24 h long-term conditions and post urethane injection. Relative EEG power values (%) for 2 s epochs were analysed for the following frequency ranges: delta 1 ( δ 1 , 0.5–4 Hz), delta 2 ( δ 2 , 1–4 Hz), theta 1 ( θ 1 , 4–8 Hz), theta 2 ( θ 2 , 4–12 Hz), alpha ( α , 8–12 Hz), sigma ( σ , 12–16 Hz), beta 1 ( β 1 , 12–30 Hz), beta 2 ( β 2 , 16–24 Hz), beta 3 ( β 3 , 16–30 Hz), gamma low ( γ l o w , 30–50 Hz), gamma mid ( γ m i d , 50–70 Hz), gamma high ( γ h i g h , 70–100 Hz), gamma ripples ( γ r i p p l e s , 80–200 Hz), and gamma fast ripples ( γ f a s t r i p p l e s , 200–500 Hz). In addition, subcutaneous temperature and relative activity data were analysed for both the light and dark cycle of two long-term recordings. The same type of data was obtained post urethane injection. Detailed information is provided for the age and body weight of the experimental animals, the technical specifications of the radiofrequency transmitter, the stereotaxic coordinates for the intracerebral, deep and epidural, surface EEG electrodes, the electrode features, the filtering and sampling characteristics, the analysed EEG frequency bands and the data acquisition parameters. EEG power data, temperature and activity data are available at MENDELEY DATA (doi: 10.17632/x53km5sby6.1 , URL: http://dx.doi.org/10.17632/x53km5sby6.1 ). Raw EEG data are available at zenodo ( https://zenodo.org/ ). |
Databáze: | OpenAIRE |
Externí odkaz: |