Simultaneous quantitation of sixteen organochlorine pesticides in drinking waters using automated solid-phase extraction, high-volume injection, high-resolution gas chromatography
Autor: | Ian A. Fowlis, Wendy C. Quayle, Ivan Jepson |
---|---|
Rok vydání: | 1997 |
Předmět: |
Insecticides
Autoanalysis Chromatography Gas Chromatography Chemistry Elution Microchemistry Organic Chemistry Extraction (chemistry) Reproducibility of Results Water General Medicine Biochemistry Analytical Chemistry Cartridge Electron capture detector Tap water Hydrocarbons Chlorinated Water Pollutants Gas chromatography Solid phase extraction Quantitative analysis (chemistry) |
Zdroj: | Journal of Chromatography A. 773:271-276 |
ISSN: | 0021-9673 |
DOI: | 10.1016/s0021-9673(97)00190-8 |
Popis: | A method is described for the simultaneous determination of sixteen organochlorine pesticides in drinking water using automated solid-phase extraction followed by high-volume (80 μl) injection capillary column gas chromatography using electron capture detection. The fully automated extraction method followed by high-volume injection permits rapid sample analysis compared to previously described procedures since no further pre-concentration of the analytes is necessary after they have been eluted from the octadecyl solid-phase extraction cartridge. The lowest detectable concentrations of the pesticides are between 1–5 ng l −1 , relative recoveries range from 92–105% in tap water spiked at 100 ng l −1 and the relative standard deviations are in the range 5–12%. |