Neuromechanical coupling during mechanical ventilation: reverse-triggering vs others forms of asynchrony
Autor: | J.A. Benítez Lozano, J.M. Serrano Simón, F. Ruiz Ferrón, P. Carmona Sánchez |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2015 |
Předmět: |
Mechanical ventilation
medicine.medical_specialty business.industry medicine.medical_treatment Critical Care and Intensive Care Medicine Rhythm Inspiratory flow Anesthesia Internal medicine Poster Presentation Cardiology medicine Respiratory effort Esophageal pressure Respiratory system Entrainment (chronobiology) business |
Zdroj: | Intensive Care Medicine Experimental |
ISSN: | 2197-425X |
Popis: | The term “respiratory entrainment” refers to of coupling patterns between the rhythm neuronal and mechanical of ventilator to achieve satisfactory synchrony. Respiratory effort stimulated by the mechanical inspiratory flow or reverse trigger (RT), has been recently demonstrated [1]. This asynchrony is difficult to showed without additional signals as esophageal pressure or electrodiaphragmatic signal. |
Databáze: | OpenAIRE |