Captopril renography and duplex Doppler sonography in the diagnosis of renovascular hypertension
Autor: | Staša Kaplan-Pavlovčič, C Nadja |
---|---|
Rok vydání: | 1998 |
Předmět: |
Adult
Male Duplex ultrasonography medicine.medical_specialty Captopril Kidney urologic and male genital diseases Renal artery stenosis Scintigraphy Sensitivity and Specificity Renovascular hypertension Predictive Value of Tests medicine.artery medicine Humans Prospective Studies Renal artery Radionuclide Imaging Aged Ultrasonography Doppler Duplex Transplantation medicine.diagnostic_test business.industry Angioplasty Angiography Middle Aged medicine.disease Hypertension Renovascular medicine.anatomical_structure Nephrology ACE inhibitor Female Radiology business circulatory and respiratory physiology medicine.drug |
Zdroj: | Nephrology Dialysis Transplantation. 13:313-317 |
ISSN: | 1460-2385 0931-0509 |
Popis: | BACKGROUND The purpose of this prospective study was to determine the clinical usefulness of captopril renal scintigraphy and duplex Doppler sonography in detecting haemodynamically significant renal artery stenosis (> or = 60%) and predicting cure or improvement of hypertension following revascularisation. METHODS Twenty-eight patients with moderate or high index of clinical suspicion of renovascular hypertension underwent both captopril renal scintigraphy and duplex Doppler sonography before undergoing renal angiography. Patients with angiographically proved (> or = 60%) RAS were treated by percutaneous transluminal renal angioplasty unless it was contraindicated. RESULTS The results of captopril renal scintigraphy and duplex Doppler sonography were compared by renal angiography of 45 renal arteries in 28 patients. Eleven renal arteries were excluded from further comparison, because no accurate Doppler signal could be obtained. The sensitivity and specificity of captopril renal scintigraphy in the identification of RAS (> or = 60%) was 78% and 81% respectively. The sensitivity of duplex Doppler sonography was 83% and the specificity was 81%. Positive predictive values of both tests for blood pressure cure or improvement after PTRA were 86% for CRS and 85% for DDS. CONCLUSIONS Captopril renal scintigraphy and duplex Doppler sonography are comparable tests for detection of patients with haemodynamically significant renal artery stenosis (> or = 60%). Positive predictive values of both tests for cure or improvement of hypertension after percutaneous transluminal renal angioplasty are good and comparable. |
Databáze: | OpenAIRE |
Externí odkaz: |