Calibration of thin-foil manganin gauge in ALOX material

Autor: L. J. Weirick, R. A. Benham, L. M. Lee
Rok vydání: 1996
Předmět:
Zdroj: AIP Conference Proceedings.
ISSN: 0094-243X
Popis: The purpose of this program was to develop a calibration curve (stress as a function of change in gauge resistance/gauge resistance) and to obtain gauge repeatability data for Micro-Measurements stripped manganin thin-foiled gauges up to 6.1 GPa in ALOX (42% by volume alumina in Epon 828 epoxy) material. A light-gas gun was used to drive an ALOX impactor into the ALOX target containing four gauges in a centered diamond arrangement. Tilt and velocity of the impactor were measured along with the gauge outputs. Impact stresses from 0.5 to 6.1 GPa were selected in increments of 0.7 GPa with duplicate tests done at 0.5, 3.3 and 6.1 GPa. A total of twelve tests were conducted using ALOX. Three initial tests were done using polymethyl methacrylate (PMMA) as the impactor and target at an impact pressure of 3.0 GPa for comparison of gauge output with analysis and literature values. The installed gauge, stripped of its backing, has a nominal thickness of 5 {micro}m. The thin gauge and high speed instrumentation allowed higher time resolution measurements than can be obtained with manganin wire.
Databáze: OpenAIRE