Measurement of SARS-CoV-2 in air and on surfaces in Scottish hospitals

Autor: Miranda, Loh, Nicola, Yaxley, Ginny, Moore, David, Holmes, Susanne, Todd, Alice, Smith, Ewan, Macdonald, Sean, Semple, Mark, Cherrie, Manish, Patel, Raymond, Hamill, Alastair, Leckie, Stephanie J, Dancer, John W, Cherrie
Rok vydání: 2023
Předmět:
Zdroj: Journal of Hospital Infection. 133:1-7
ISSN: 0195-6701
DOI: 10.1016/j.jhin.2022.11.019
Popis: There are still uncertainties in our knowledge of the amount of SARS-CoV-2 virus present in the environment; where it can be found, and potential exposure determinants, limiting our ability to effectively model and compare interventions for risk management.This study measured SARS-CoV-2 in three hospitals in Scotland on surfaces and air, alongside ventilation and patient care activities.Air sampling at 200 L/min for 20 minutes and surface sampling were performed in two wards designated to treat COVID-19 -positive patients and two non-COVID-19 wards across three hospitals in November and December 2020.Detectable samples of SARS-CoV-2 were found in COVID-19 treatment wards but not in non-COVID-19 wards. Most samples were below assay detection limits, but maximum concentrations reached 1.7x10Non-patient areas of the hospital may pose risks for infection transmission and further attention should be paid to these areas. Standardization of sampling methods will improve understanding of levels of environmental contamination. The pandemic has demonstrated a need to review and act upon the challenges of older hospital buildings meeting current ventilation guidance.
Databáze: OpenAIRE