Stabilising system frequency using HVDC between the Continental European, Nordic, and Great Britain systems
Autor: | Jes Jerom de Haan, Madeleine Gibescu, Carolina Escudero Concha, WL Wil Kling, Gerard Doorman, Jan van Putten |
---|---|
Přispěvatelé: | Electrical Energy Systems |
Jazyk: | angličtina |
Rok vydání: | 2016 |
Předmět: |
Engineering
Primary control Process (engineering) 020209 energy media_common.quotation_subject Control (management) Energy Engineering and Power Technology 02 engineering and technology Electric power system 0202 electrical engineering electronic engineering information engineering Quality (business) SDG 7 - Affordable and Clean Energy Electrical and Electronic Engineering media_common Interconnection Renewable Energy Sustainability and the Environment business.industry Virtual inertia Control engineering Power system balancing Reliability engineering Power (physics) Interdependence Work (electrical) Control and Systems Engineering Frequency sensitivity business SDG 7 – Betaalbare en schone energie |
Zdroj: | Sustainable Energy, Grids and Networks, 5, 125-134. Elsevier |
ISSN: | 2352-4677 |
Popis: | For future efficiency improvement of the frequency containment process (primary control) within European power systems, cooperation between (multiple) synchronous areas using their controllable HVDC interconnections is optioned. However, the differences in system size, HVDC interconnection capacity, and the balancing performance per individual system will have its specific system frequency effect for each different balancing cooperation concept. Consequently, without alignment on cooperation, HVDC balancing might lead to disproportional support between systems, to frequency oscillations, reserve unreliability and non-compliancy, and to network constraints. Therefore, this work assesses frequency quality and associated DC power flows for several balancing arrangements, using a developed load-frequency control model with frequency interdependency for coupled power system. For a trilateral balancing cooperation case study, it is found that certain cooperation concepts result in undesired frequency oscillation and poor frequency quality. However, cooperation where especially fast-response services are shared, such as virtual inertia, show improved system frequency performance. For the case where power imbalances are proportionately distributed among the systems, it is concluded that power transfers over HVDC interconnections are limited and additional control optimisation can be performed. Those concepts with aligned central or coordinated control show best results for a future cooperation for balancing between synchronous areas. |
Databáze: | OpenAIRE |
Externí odkaz: |