The Rule of 10: a simple 3D ultrasonographic method for the diagnosis of T-shaped uterus
Autor: | Simone Garzon, Antonio Simone Laganà, Luis Alonso Pacheco, Jose Carugno, Carmina Bermejo López, Pedro Azumendi Gómez, Pilar Martinez-Ten |
---|---|
Rok vydání: | 2021 |
Předmět: |
T-shaped uterus
Uterus Diagnostic accuracy Likelihood ratios in diagnostic testing Diagnosis medicine Humans 3D ultrasound Ultrasonography Receiver operating characteristic medicine.diagnostic_test business.industry Uterine malformations Curve analysis Obstetrics and Gynecology General Medicine medicine.disease medicine.anatomical_structure Case-Control Studies Urogenital Abnormalities Female Uterine cavity Nuclear medicine business |
Zdroj: | Archives of Gynecology and Obstetrics. 304:1213-1220 |
ISSN: | 1432-0711 0932-0067 |
DOI: | 10.1007/s00404-021-06147-y |
Popis: | To investigate and propose a new simple tridimensional (3D) ultrasonographic method to diagnose a T-shaped uterus (Class U1a). A multicenter non-experimental case–control diagnostic accuracy study was conducted between January 2018 and December 2019, including 50 women (cases) diagnosed with T-shaped uterus (U1a class) and 50 women with a “normal uterus” (controls). All the enrolled women underwent 3D ultrasound, drawing four lines and recording the length of three of them as follow: draw and measure the interostial line (R0); draw from the midpoint of R0 a perpendicular line length 20 mm; draw and measure in the uterine cavity a line parallel to R0 at 10 mm below R0 (R10) and a second line parallel to R0 at 20 mm below R0 (R20). The diagnostic performance of all sonographic parameters statistically significantly different between T-shaped and normal uteri was estimated using the receiver operator characteristic (ROC) curve analysis. R10 and R20 were statistically significantly shorter in the T-shaped than the normal uterus. R10 reported the highest diagnostic accuracy with an area under the ROC curve of 0.973 (95% CI 0.940–1.000). R10 length maximizing the Youden’s J statistic was 10.5 mm. Assuming R10 length equal to or shorter than 10 mm as the cut off value for defining a woman as having a T-shaped uterus, the new ultrasonographic method following the proposed protocol (R0, R10, and R20) reported sensitivity for T-shaped uterus of 91.1% (95% CI 0.78–0.97%) and a specificity of 100% (95% CI 0.89–100%). The positive likelihood ratio was higher than 30, and the negative likelihood ratio was 0.09 (95% CI 0.04–0.26). Measuring the length of the intracavitary line parallel to the interostial line at 10 mm from it and using a length ≤ of 10 mm as cut off value (the “Rule of 10”) appears a simple and accurate 3D ultrasonographic method for the diagnosis of a T-shaped uterus. |
Databáze: | OpenAIRE |
Externí odkaz: |