Real-time intracochlear imaging of automated cochlear implant insertions in whole decalcified cadaver cochleas using ultrasound
Autor: | Manohar Bance, Guy Earle, Jeremy A. Brown, Thomas G. Landry |
---|---|
Rok vydání: | 2018 |
Předmět: |
Materials science
medicine.medical_treatment 03 medical and health sciences Speech and Hearing 0302 clinical medicine Optical coherence tomography Cadaver Cochlear implant Image Processing Computer-Assisted medicine Humans 030223 otorhinolaryngology Cochlea Ultrasonography medicine.diagnostic_test business.industry Ultrasound Cochlear Implantation Basilar Membrane Basilar membrane Surgery Computer-Assisted Otorhinolaryngology Ultrasound imaging Feasibility Studies Implant business 030217 neurology & neurosurgery Biomedical engineering |
Zdroj: | Cochlear Implants International. 19:255-267 |
ISSN: | 1754-7628 1467-0100 |
Popis: | This study aimed to determine the feasibility of combining high-frequency ultrasound imaging, automated insertion, and force sensing to yield more information about cochlear implant insertion dynamics.An apparatus was developed combining these aspects along with software to control implant and imaging probe positions. Decalcified unfixed human cochleas were implanted at various speeds, insertion sites, and implant models while imaging near the implant tip throughout insertion and recording force data from the cochlea mounting stage. Ultrasound video data were also captured.The basilar membrane (BM) was frequently penetrated by the implant in either the mid-basal or lower middle turn. Measurements were also performed of apical BM motion in response to upstream implant movement at varying insertion speeds. Increasing insertion speed resulted in greater BM displacement.Multiple insertions per cochlea increase the volume of data per specimen while also reducing variability due to differences between cochleas. However, to image inside the cochlea with ultrasound, the bone had to be decalcified, which likely had a significant effect upon the response of tissue to contact by the implant. As calcified bone strongly reflects ultrasound, we also found ultrasound imaging to be an excellent method for easily assessing bone decalcification progress.This technique may be very useful for some studies, although the confounding effects of bone decalcification may make results of other studies too difficult to generalize. The approach could be adapted to other real-time imaging modalities, such as optical coherence tomography. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |