Popis: |
A sequence of three programs is described for the collection and subsequent analysis of auditory evoked potentials using a PDP-12 computer. The first program (AVEF) controls stimulus generating equipment, and collects, tags, displays, and stores individual responses. The second program (SUPRSNAP) performs a latency and amplitude analysis on the various peaks within preselected time windows of the response waveform and stores the data. The third program (SUPRSTAT) summarizes by individual peak the results of the analyses, and calculates the mean, standard deviation, and confidence interval of the individual peaks, differentially retrieved by the use of various tag sets. |