State of the art in breast intraoperative electron radiation therapy after intraoperative ultrasound introduction

Autor: Sara Savatovic, Gerd Fastner, Cristiana Vidali, Marina Bortul, Mara Severgnini, Serena Scomersi, Zaira Pellin, Gabriele Bellio, Vittorino Milan, A. Ciabattoni, Fabiola Giudici
Přispěvatelé: Vidali, Cristiana, Severgnini, Mara, Bellio, Gabriele, Giudici, Fabiola, Milan, Vittorino, Pellin, Zaira, Savatovic, Sara, Scomersi, Serena, Fastner, Gerd, Ciabattoni, Antonella, Bortul, Marina
Jazyk: angličtina
Rok vydání: 2021
Předmět:
medicine.medical_treatment
R895-920
030218 nuclear medicine & medical imaging
Medical physics. Medical radiology. Nuclear medicine
0302 clinical medicine
Retrospective Studie
80 and over
Clinical endpoint
skin and connective tissue diseases
Radiation Injurie
Ultrasonography
Aged
80 and over

Interventional
ultrasound
Ultrasound
Fascia
Middle Aged
medicine.anatomical_structure
Oncology
030220 oncology & carcinogenesis
Female
Intraoperative electron radiation therapy
Breast Neoplasm
Research Article
Human
Adult
Film Dosimetry
Breast Neoplasms
Electrons
Electron
03 medical and health sciences
Breast cancer
breast cancer
Radiation Protection
whole breast radiotherapy
medicine
Humans
intraoperative electron radiation therapy
Aged
Intraoperative Care
Radiation Injuries
Retrospective Studies
Ultrasonography
Interventional

Radiology
Nuclear Medicine and imaging

business.industry
Partial Breast Irradiation
medicine.disease
Acute toxicity
Radiation therapy
Nuclear medicine
business
Zdroj: Radiology and Oncology, Vol 55, Iss 3, Pp 333-340 (2021)
Radiology and Oncology
Popis: Background Breast intraoperative electron radiation therapy (B-IOERT) can be used in clinical practice both as elective irradiation (partial breast irradiation – APBI) in low risk breast cancer patients, and as an anticipated boost. The procedure generally includes the use of a shielding disk between the residual breast and the pectoralis fascia for the protection of the tissues underneath the target volume. The aim of the study was to evaluate the role of intraoperative ultrasound (IOUS) in improving the quality of B-IOERT. Patients and methods B-IOERT was introduced in Trieste in 2012 and its technique was improved in 2014 with IOUS. Both, needle and IOUS were used to measure target thickness and the latter was used even to check the correct position of the shielding disk. The primary endpoint of the study was the evaluation of the effectiveness of IOUS in reducing the risk of a disk misalignment related to B-IOERT and the secondary endpoint was the analysis of acute and late toxicity, by comparing two groups of patients treated with IOERT as a boost, either measured with IOUS and needle (Group 1) or with needle alone (Group 2). Acute and late toxicity were evaluated by validated scoring systems. Results From the institutional patients who were treated between June 2012 and October 2019, 109 were eligible for this study (corresponding to 110 cases, as one patients underwent bilateral conservative surgery and bilateral B-IOERT). Of these, 38 were allocated to group 1 and 72 to group 2. The target thickness measured with the IOUS probe and with the needle were similar (mean difference of 0.1 mm, p = 0.38). The percentage of patients in which the shield was perfectly aligned after IOUS introduction increased from 23% to more than 70%. Moreover, patients treated after IOUS guidance had less acute toxicity (36.8% vs. 48.6%, p = 0.33) from radiation therapy, which reached no statistical significance. Late toxicity turned out to be similar regardless of the use of IOUS guidance: 39.5% vs. 37.5% (p = 0.99). Conclusions IOUS showed to be accurate in measuring the target depth and decrease the misalignment between collimator and disk. Furthermore there was an absolute decrease in acute toxicity, even though not statistically significant, in the group of women who underwent B-IOERT with IOUS guidance.
Databáze: OpenAIRE