Cardiac Tamponade due to Left Ventricular Pseudoaneurysm After Aortic Valve Replacement
Autor: | İnci Firatli, Mehmet Serdar Küçükoğlu, Gürkan Çetin, Murat Ersanli, Onur Baydar, Betul Balaban, Ugur Coskun |
---|---|
Rok vydání: | 2013 |
Předmět: |
Adult
Heart Defects Congenital medicine.medical_specialty Heart Ventricles Heart Valve Diseases Dehiscence Pseudoaneurysm Aneurysm Bicuspid Aortic Valve Disease Aortic valve replacement Internal medicine Cardiac tamponade medicine Humans Ventricular outflow tract Endocarditis cardiovascular diseases Heart Valve Prosthesis Implantation business.industry medicine.disease Cardiac Tamponade Surgery Treatment Outcome Aortic Valve cardiovascular system Cardiology Female Cardiology and Cardiovascular Medicine business Complication Aneurysm False |
Zdroj: | The Heart Surgery Forum. 16:49 |
ISSN: | 1522-6662 1098-3511 |
Popis: | Left ventricular outflow tract pseudoaneurysm is a rare but a potentially lethal complication, mainly after aortic root endocarditis or surgery. Usually, it originates from a dehiscence in the mitral-aortic intervalvular fibrosa and arises posteriorly to the aortic root. We report a rare case of a patient with cardiac tamponade due to left ventricular pseudoaneurysm after aortic valve replacement. The subsequent surgical resection was performed successfully. |
Databáze: | OpenAIRE |
Externí odkaz: |