Nebulizadores: fonte de contaminação bacteriana em pacientes com fibrose cística?
Autor: | Lorena Xavier Costa Brzezinski, Helena Homem de Melo de Souza, Nelson Rosario, Paulo Kussek, Carlos Antônio Riedi |
---|---|
Jazyk: | portugalština |
Rok vydání: | 2011 |
Předmět: |
Pulmonary and Respiratory Medicine
medicine.medical_specialty Nebulizadores e vaporizadores business.industry Cross-sectional study Pseudomonas aeruginosa Contamination medicine.disease_cause medicine.disease Sputum sample Cystic fibrosis Surgery Disinfection Nebulizer Internal medicine Nebulizers and vaporizers Medicine Sputum In patient Fibrose cística Desinfecção medicine.symptom business |
Zdroj: | Jornal Brasileiro de Pneumologia v.37 n.3 2011 Jornal Brasileiro de Pneumologia Sociedade Brasileira de Pneumologia e Tisiologia (SBPT) instacron:SBPT Jornal Brasileiro de Pneumologia, Volume: 37, Issue: 3, Pages: 341-347, Published: JUN 2011 |
Popis: | OBJETIVO: Determinar se os nebulizadores de pacientes com fibrose cística são fonte de contaminação microbiana e verificar se a técnica e a frequência de desinfecção dos nebulizadores é apropriada. MÉTODOS: Estudo de corte transversal observacional, sem grupo controle. Foram coletadas amostras de 28 pacientes com fibrose cística, no domicílio do paciente, sem aviso prévio sobre o motivo da visita. Foram colhidas três amostras por paciente: do reservatório do nebulizador, da máscara/bocal e do próprio paciente (swab da orofaringe/escarro). As amostras foram acondicionadas adequadamente e levadas para análise. Os pacientes, seus pais ou responsáveis preencheram um questionário sobre métodos de limpeza e desinfecção dos nebulizadores. RESULTADOS: Foram obtidas 84 amostras dos 28 pacientes. Destes, 15 (53,5%) eram do gênero masculino. A mediana de idade foi de 11 anos (variação: 1-27 anos). Dos 28 pacientes, 15 apresentaram culturas de escarro/orofaringe positivas. As bactérias encontradas com maior frequencia foram Streptococcus aureus (8/15) e Pseudomonas aeruginosa (4/15). A cultura obtida dos nebulizadores identificou diversos patógenos, sem nenhum predominante. Não houve associações entre os resultados das culturas obtidas dos nebulizadores e aquelas dos pacientes em 27 casos (96,7%). A limpeza e a desinfecção não eram realizadas de forma adequada em 22 casos (78,6%). CONCLUSÕES: Nesta amostra de pacientes, apesar das técnicas de desinfecção inadequadas, os nebulizadores não foram uma fonte de contaminação microbiana OBJECTIVE: To determine whether nebulizers are a source of microbial contamination in patients with cystic fibrosis, as well as whether the technique and frequency of disinfection of these devices is appropriate. METHODS: This was a cross-sectional, uncontrolled observational study. Samples were collected from 28 patients with cystic fibrosis. Samples were collected at the homes of the patients, who were not previously informed of the purpose of the visit. Three samples were collected from each patient: one from the nebulizer chamber, one from the mask/mouthpiece, and one from the patient (oropharyngeal swab /sputum). The samples were properly stored and taken for analyses. The patients, their parents, or their legal guardians completed a questionnaire regarding nebulizer cleaning and disinfecting methods. RESULTS: We collected 84 samples from the 28 patients. Of those 28 patients, 15 (53.5%) were male. The median age of the patients was 11 years (range, 1-27 years). Of the 28 patients, 15 presented with positive oropharyngeal swab /sputum sample cultures. The most common bacterial isolates were Staphylococcus aureus (in 8 patients) and Pseudomonas aeruginosa (in 4 patients). Although the samples obtained from the nebulizers presented with various pathogens in culture, no specific species predominated. In 27 cases (96.7%), there were no associations between the samples obtained from the nebulizers and those obtained from the patients in terms of the results of the cultures. Cleaning and disinfection of nebulizers were inappropriate in 22 cases (78.6%). CONCLUSIONS: In this sample of patients, despite the inappropriate disinfection techniques, nebulizers were not found to be a source of microbial contamination |
Databáze: | OpenAIRE |
Externí odkaz: |