Large Diameter Total Hip Replacement for Acute Displaced Femoral Neck Fracture
Autor: | James W. Pritchett |
---|---|
Rok vydání: | 2019 |
Předmět: |
Male
Reoperation medicine.medical_specialty Prosthesis-Related Infections Arthroplasty Replacement Hip Radiography 0206 medical engineering Biomedical Engineering Periprosthetic 02 engineering and technology Femoral Neck Fractures Femoral head Femoracetabular Impingement medicine Hip Dislocation Humans Range of Motion Articular General Dentistry Aged Femoral neck business.industry Equipment Design Middle Aged 020601 biomedical engineering Prosthesis Failure Surgery medicine.anatomical_structure Harris Hip Score Acute Disease Orthopedic surgery Trunnion Female Hip Joint Periprosthetic Fractures business Follow-Up Studies |
Zdroj: | Journal of Long-Term Effects of Medical Implants. 29:71-78 |
ISSN: | 1050-6934 |
DOI: | 10.1615/jlongtermeffmedimplants.2019030607 |
Popis: | Background Total hip replacement for acute femoral neck fracture is the preferred treatment for younger, physically and socially active patients. The risks, particularly dislocation, are higher than for elective total hip replacement for arthritis. Larger diameter bearings provide increased stability and can be used in this higher risk setting. Methods In this study, 391 patients with acute femoral neck fractures were treated with total hip replacement using 40-mm and 44-mm femoral heads. These femoral heads were placed in thin, two-piece, highly cross-linked polyethylene-lined acetabular shells. The procedures were performed by community orthopedic surgeons using the posterior approach. Patients were mobilized immediately and with only routine postoperative precautions. Patients were followed for 5 years. Follow-up radiographs were measured to determine component position. Results There were no dislocations in the first 3 years following surgery, but there were 3 late dislocations. There were 29 revisions performed for impingement (n = 8), infection (n = 12), periprosthetic fracture (n = 3), instability (n = 2), and component loosening (n = 4). No instances of polyethylene wear or trunnion corrosion were identified. Overall, 37% of acetabular components simultaneously met the safe zone targets for inclination and anteversion. The mean Harris hip score was 90. Conclusions The dislocation rate in this study was lower than in prior studies, as was the overall revision rate. Using a femoral head ≥ 40 mm is a simple measure that reduces the dislocation rate without adding additional cost or complexity to the procedure. This device is available to all surgeons and may be an advantage to the hip surgeon treating femoral neck fractures with total hip replacement. |
Databáze: | OpenAIRE |
Externí odkaz: |