Development and validation of HPLC method for the determination of Cyclosporin A and its impurities in Neoral® capsules and its generic versions
Autor: | M. Giocanti, Jean-Pierre Reynier, B. Lacarelle, F. Nunes Bonifacio, Alain Nicolay |
---|---|
Rok vydání: | 2009 |
Předmět: |
Quality Control
Clinical Biochemistry Pharmaceutical Science Capsules Sensitivity and Specificity High-performance liquid chromatography Dosage form Analytical Chemistry Cyclosporin a Spectrophotometry Drug Discovery medicine Drugs Generic Hplc method Chromatography High Pressure Liquid Spectroscopy Detection limit Chromatography Isocratic elution Molecular Structure medicine.diagnostic_test Chemistry Reproducibility of Results Reference Standards Allograft rejection Calibration Cyclosporine Spectrophotometry Ultraviolet Drug Contamination Immunosuppressive Agents |
Zdroj: | Journal of Pharmaceutical and Biomedical Analysis. 49:540-546 |
ISSN: | 0731-7085 |
DOI: | 10.1016/j.jpba.2008.11.027 |
Popis: | Cyclosporin A (CyA) is a cornerstone immunosuppressant for the prophylaxis against allograft rejection after organ transplantation. The most widely prescribed CyA formulation is Neoral soft gelatine capsules (Novartis Pharmaceuticals, Basel, Switzerland). After Novartis patent expiration, several generic formulations have been developed. In this paper, a simple and reliable HPLC method was developed and validated for the evaluation of four CyA degradation products (ID-005-95, CyH, IsoCyH and IsoCyA) and two related compounds (CyB and CyG) aimed for the quality control of Neoral capsules and its generic formulations. In a second step, the validated method was then compared to the USP assay method for capsules, where some of the mentioned impurities were not adequately resolved from the CyA peak. Isocratic elution at a flow rate of 1.0mLmin(-1) was employed on a Lichrospher RP-18 (4mmx250mm; 5microm) analytical column maintained at 75 degrees C with a tetrahydrofuran:phosphoric acid (0.05M) (44:56, v/v) as mobile phase. The chromatograms were recorded using a Hewlett Packard 1100 chromatographic system. The UV detection wavelength was performed at 220nm and 10microL of sample was injected. The developed method was validated in terms of selectivity, linearity, precision, accuracy, limit of detection and limit of quantitation. The validate method was successfully applied to commercial capsules, Neoral and generic versions. Therefore, the proposed method is suitable for the simultaneous determination of CyA as well as its major impurities. |
Databáze: | OpenAIRE |
Externí odkaz: |