Potency assays for anistreplase: Comparison of the fibrin plate assay and a 96-well plate assay

Autor: Patrick J. Gaffney, D.M.V. van Schie, Deborah P. Beebe
Rok vydání: 1992
Předmět:
Zdroj: Biologicals. 20:129-133
ISSN: 1045-1056
DOI: 10.1016/s1045-1056(05)80060-0
Popis: Several production lots of Anistreplase (Eminase) were assayed for potency by either two fibrin plate assays or a clot lysis assay performed in 96-well microtiter plates. The 96-well plate assay yielded comparable data to the fibrin plate assays and had the advantage of greater efficiency with respect to both time and reagents. As a result the newer method appears to be a suitable alternative to the fibrin plate assays for lot release of Anistreplase.