Infant polysomnography: reliability and validity of infant arousal assessment
Autor: | Lee J. Brooks, Debra E. Weese-Mayer, David H. Crowell, Linda E. Kapuniai, Michael J. Corwin, Sally L. Davidson Ward, Thomas D. Kulp, Mark Peucker, Larry R. Tinsley, Jean M. Silvestri, Carl E. Hunt |
---|---|
Rok vydání: | 2002 |
Předmět: |
Male
medicine.medical_specialty Time Factors Physiology Concordance Polysomnography Electroencephalography Audiology Arousal Developmental psychology Physiology (medical) medicine Humans Wakefulness Reliability (statistics) Observer Variation medicine.diagnostic_test Infant Reproducibility of Results Videotape Recording Signal Processing Computer-Assisted Intra-rater reliability Sudden infant death syndrome Inter-rater reliability Neurology Female Neurology (clinical) Sleep Stages Psychology |
Zdroj: | Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society. 19(5) |
ISSN: | 0736-0258 |
Popis: | Infant arousal scoring based on the Atlas Task Force definition of transient EEG arousal was evaluated to determine (1). whether transient arousals can be identified and assessed reliably in infants and (2). whether arousal and no-arousal epochs scored previously by trained raters can be validated reliably by independent sleep experts. Phase I for inter- and intrarater reliability scoring was based on two datasets of sleep epochs selected randomly from nocturnal polysomnograms of healthy full-term, preterm, idiopathic apparent life-threatening event cases, and siblings of Sudden Infant Death Syndrome infants of 35 to 64 weeks postconceptional age. After training, test set 1 reliability was assessed and discrepancies identified. After retraining, test set 2 was scored by the same raters to determine interrater reliability. Later, three raters from the trained group rescored test set 2 to assess inter- and intrarater reliabilities. Interrater and intrarater reliability kappa's, with 95% confidence intervals, ranged from substantial to almost perfect levels of agreement. Interrater reliabilities for spontaneous arousals were initially moderate and then substantial. During the validation phase, 315 previously scored epochs were presented to four sleep experts to rate as containing arousal or no-arousal events. Interrater expert agreements were diverse and considered as noninterpretable. Concordance in sleep experts' agreements, based on identification of the previously sampled arousal and no-arousal epochs, was used as a secondary evaluative technique. Results showed agreement by two or more experts on 86% of the Collaborative Home Infant Monitoring Evaluation Study arousal scored events. Conversely, only 1% of the Collaborative Home Infant Monitoring Evaluation Study-scored no-arousal epochs were rated as an arousal. In summary, this study presents an empirically tested model with procedures and criteria for attaining improved reliability in transient EEG arousal assessments in infants using the modified Atlas Task Force standards. With training based on specific criteria, substantial inter- and intrarater agreement in identifying infant arousals was demonstrated. Corroborative validation results were too disparate for meaningful interpretation. Alternate evaluation based on concordance agreements supports reliance on infant EEG criteria for assessment. Results mandate additional confirmatory validation studies with specific training on infant EEG arousal assessment criteria. |
Databáze: | OpenAIRE |
Externí odkaz: |