Popis: |
Computational studies have been carried out showing the complex time dependence of uncertainties in nuclear concentrations of various nuclides arising from the propagation of the neutron flux density errors in the burnup calculation process in cells with different neutron spectra on the above errors. It is found that these uncertainties not only depend on the burnup time in a complex way, but also depend on the spectrum of the cell. The variants of the cell with thermal and fast neutron spectra were considered. The calculations were performed using the VisualBurnOut program (Kolesov et al. 2009), which makes it possible to estimate these uncertainties arising due to errors in the input parameters of the burnup problem (reaction rates, neutron flux density, etc.). The influence of the number of calculated burnup points on the results of burnup calculations by the Monte Carlo method was investigated. Uncertainties arising in nuclear concentrations at intermediate calculation steps due to errors in nuclear concentrations appearing at the previous step were taken into account in the calculations. |