Functional assessments of foot strength: a comparative and repeatability study

Autor: Drew H. Ferguson, Sarah T. Ridge, Kirk E. Bassett, A. Wayne Johnson, Mark T. Olsen, Dallin W. Griffin, Dustin A. Bruening, Julia L. Jacobs
Rok vydání: 2019
Předmět:
Zdroj: BMC Musculoskeletal Disorders
BMC Musculoskeletal Disorders, Vol 20, Iss 1, Pp 1-9 (2019)
ISSN: 1471-2474
Popis: Background Evaluating the strength of the small muscles of the foot may be useful in a variety of clinical applications but is challenging from a methodology standpoint. Previous efforts have focused primarily on the functional movement of toe flexion, but clear methodology guidelines are lacking. A novel foot doming test has also been proposed, but not fully evaluated. The purposes of the present study were to assess the repeatability and comparability of several functional foot strength assessment techniques. Methods Forty healthy volunteers were evaluated across two testing days, with a two-week doming motion practice period between them. Seven different measurements were taken using a custom toe flexion dynamometer (seated), custom doming dynamometer (standing), and a pressure mat (standing). Measurements from the doming dynamometer were evaluated for reliability (ICCs) and a learning effect (paired t-tests), while measurements from the toe flexion dynamometer and pressure mat were evaluated for reliability and comparability (correlations). Electromyography was also used to descriptively assess the extent of muscle isolation in all measurements. Results Doming showed excellent within-session reliability (ICCs > 0.944), but a clear learning effect was present, with strength (p 0.945). Seated toe flexion tests using the dynamometer were moderately correlated to standing toe flexion tests on a pressure mat (r > 0.54); however, there were some differences in muscle activity. The former may better isolate the toe flexors, while the latter appeared to be more functional for many pathologies. On the pressure mat, reciprocal motion appeared to display slightly greater forces and reliability than isolated toe flexion. Conclusions This study further refines potential methodology for foot strength testing. These devices and protocols can be duplicated in the clinic to evaluate and monitor rehabilitation progress in clinical populations associated with foot muscle weakness.
Databáze: OpenAIRE
Nepřihlášeným uživatelům se plný text nezobrazuje