Sensitivity and specificity of diagnostic ultrasound in the diagnosis of phrenic neuropathy
Autor: | Leili Shahgholi Ghahfarokhi, Eric J. Sorenson, James C. Watson, Hiroshi Sekiguchi, Jeffrey A. Strommen, Andrea J. Boon, Caitlin J. Harper |
---|---|
Rok vydání: | 2014 |
Předmět: |
Adult
Male medicine.medical_specialty Radiography Diaphragm Diaphragmatic breathing Sensitivity and Specificity Article Pulmonary function testing Medicine Humans False Positive Reactions Prospective Studies Prospective cohort study Phrenic nerve Aged Ultrasonography Aged 80 and over business.industry Ultrasound Peripheral Nervous System Diseases Middle Aged musculoskeletal system Surgery Diaphragm (structural system) Phrenic Nerve Dyspnea Respiratory failure Feasibility Studies Female Neurology (clinical) Radiology business Respiratory Insufficiency |
Zdroj: | Neurology. 83(14) |
ISSN: | 1526-632X |
Popis: | Objectives: To determine the sensitivity and specificity of B-mode ultrasound in the diagnosis of neuromuscular diaphragmatic dysfunction, including phrenic neuropathy. Methods: A prospective study of patients with dyspnea referred to the EMG laboratory over a 2-year time frame for evaluation of neuromuscular respiratory failure who were recruited consecutively and examined with ultrasound for possible diaphragm dysfunction. Sonographic outcome measures were absolute thickness of the diaphragm and degree of increased thickness with maximal inspiration. The comparison standard for diagnosis of diaphragm dysfunction was the final clinical diagnosis of clinicians blinded to the diaphragm ultrasound results, but taking into account other diagnostic workup, including chest radiographs, fluoroscopy, phrenic nerve conduction studies, diaphragm EMG, and/or pulmonary function tests. Results: Of 82 patients recruited over a 2-year period, 66 were enrolled in the study. Sixteen patients were excluded because of inconclusive or insufficient reference testing. One hemidiaphragm could not be adequately visualized; therefore, hemidiaphragm assessment was conducted in a total of 131 hemidiaphragms in 66 patients. Of the 82 abnormal hemidiaphragms, 76 had abnormal sonographic findings (atrophy or decreased contractility). Of the 49 normal hemidiaphragms, none had a false-positive ultrasound. Diaphragmatic ultrasound was 93% sensitive and 100% specific for the diagnosis of neuromuscular diaphragmatic dysfunction. Conclusion: B-mode ultrasound imaging of the diaphragm is a highly sensitive and specific tool for diagnosis of neuromuscular diaphragm dysfunction. Classification of evidence: This study provides Class II evidence that diaphragmatic ultrasound performed by well-trained individuals accurately identifies patients with neuromuscular diaphragmatic respiratory failure (sensitivity 93%; specificity 100%). |
Databáze: | OpenAIRE |
Externí odkaz: |