On-line and off-line quantification of trace elements associated to colloids by As-Fl-FFF and ICP-MS
Autor: | Gaëtane Lespes, M. Potin Gautier, I. Le Hécho, Stéphane Dubascoux |
---|---|
Přispěvatelé: | Institut des sciences analytiques et de physico-chimie pour l'environnement et les materiaux (IPREM), Université de Pau et des Pays de l'Adour (UPPA)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS) |
Jazyk: | angličtina |
Rok vydání: | 2008 |
Předmět: |
Analytical validation
Analytical chemistry 010501 environmental sciences Element analysis 01 natural sciences Analytical Chemistry Environmental impact Inductively coupled plasma mass spectrometer Fractionation Inductively coupled plasma mass spectrometry Radioactive elements Photoresists Colloid chemistry Chemistry Natural colloids Soil leachate Asymmetrical flow field Colloid size Chemical elements [SDE]Environmental Sciences Inductively coupled plasma Mass spectrometers Health impacts Liquid chromatography Fraction (chemistry) Mass spectrometry [CHIM.ANAL]Chemical Sciences/Analytical chemistry Quantification ICP-MS Optimisation Colloids 0105 earth and related environmental sciences Field flow fractionation Trace elements Chromatography 010401 analytical chemistry Trace element Trace analysis 0104 chemical sciences Lead Tin Fraction collection Leaching Analytical performances FFF Quantitative analysis (chemistry) Reference materials Agricultural chemicals |
Zdroj: | Talanta Talanta, Elsevier, 2008, 77 (1), pp.60-65. ⟨10.1016/j.talanta.2008.05.050⟩ |
ISSN: | 0039-9140 |
DOI: | 10.1016/j.talanta.2008.05.050⟩ |
Popis: | cited By 27; International audience; A quantification procedure of trace elements during colloid size fractionation was developed and validated. This procedure is based on the hyphenation between Asymmetrical Flow Field-Flow Fractionation (As-Fl-FFF) and Inductively Coupled Plasma Mass Spectrometer (ICP-MS). The optimisation of the procedure was performed on a soil leachate spiked with six trace elements selected for their environmental and health impact (As, Cd, Sb, Se, Sn and Pb). The elements in the spiked sample were on-line monitored during the fractionation. The validation was carried out by comparison with a second off-line quantification procedure based on fraction collection and total element analysis by ICP-MS. This off-line one was previously validated using reference materials. Finally, the analytical performances of the two procedures were compared. © 2008 Elsevier B.V. All rights reserved. |
Databáze: | OpenAIRE |
Externí odkaz: |