On-line and off-line quantification of trace elements associated to colloids by As-Fl-FFF and ICP-MS

Autor: Gaëtane Lespes, M. Potin Gautier, I. Le Hécho, Stéphane Dubascoux
Přispěvatelé: Institut des sciences analytiques et de physico-chimie pour l'environnement et les materiaux (IPREM), Université de Pau et des Pays de l'Adour (UPPA)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)
Jazyk: angličtina
Rok vydání: 2008
Předmět:
Analytical validation
Analytical chemistry
010501 environmental sciences
Element analysis
01 natural sciences
Analytical Chemistry
Environmental impact
Inductively coupled plasma mass spectrometer
Fractionation
Inductively coupled plasma mass spectrometry
Radioactive elements
Photoresists
Colloid chemistry
Chemistry
Natural colloids
Soil leachate
Asymmetrical flow field
Colloid size
Chemical elements
[SDE]Environmental Sciences
Inductively coupled plasma
Mass spectrometers
Health impacts
Liquid chromatography
Fraction (chemistry)
Mass spectrometry
[CHIM.ANAL]Chemical Sciences/Analytical chemistry
Quantification
ICP-MS
Optimisation
Colloids
0105 earth and related environmental sciences
Field flow fractionation
Trace elements
Chromatography
010401 analytical chemistry
Trace element
Trace analysis
0104 chemical sciences
Lead
Tin
Fraction collection
Leaching
Analytical performances
FFF
Quantitative analysis (chemistry)
Reference materials
Agricultural chemicals
Zdroj: Talanta
Talanta, Elsevier, 2008, 77 (1), pp.60-65. ⟨10.1016/j.talanta.2008.05.050⟩
ISSN: 0039-9140
DOI: 10.1016/j.talanta.2008.05.050⟩
Popis: cited By 27; International audience; A quantification procedure of trace elements during colloid size fractionation was developed and validated. This procedure is based on the hyphenation between Asymmetrical Flow Field-Flow Fractionation (As-Fl-FFF) and Inductively Coupled Plasma Mass Spectrometer (ICP-MS). The optimisation of the procedure was performed on a soil leachate spiked with six trace elements selected for their environmental and health impact (As, Cd, Sb, Se, Sn and Pb). The elements in the spiked sample were on-line monitored during the fractionation. The validation was carried out by comparison with a second off-line quantification procedure based on fraction collection and total element analysis by ICP-MS. This off-line one was previously validated using reference materials. Finally, the analytical performances of the two procedures were compared. © 2008 Elsevier B.V. All rights reserved.
Databáze: OpenAIRE