MicroELISA method for measurement of human serum thymosin alpha 1

Autor: Paul H. Naylor, Milton G. Mutchnick, David F. Keren, Frederick E. Weller, Allan L. Goldstein
Rok vydání: 1985
Předmět:
Zdroj: Journal of immunological methods. 80(1)
ISSN: 0022-1759
Popis: A microELISA for the estimation of human serum thymosin alpha 1 is described. In this assay, antibody to thymosin alpha 1 is pre-incubated with the standard or serum at 4 degrees C. Unbound antibody in the liquid-phase then binds with solid-phase thymosin alpha 1. The method is sufficiently sensitive for measuring serum levels of thymosin alpha 1 and highly reproducible. The serum levels measured with the microELISA are comparable to serum levels of thymosin alpha 1 determined by the previously described radioimmunoassay for thymosin alpha 1.
Databáze: OpenAIRE