Subjective Measures of Hearing Aid Benefit in the NIDCD/VA Clinical Trial
Autor: | Vernon D. Larson, David W. Williams, George B. Haskell, Douglas Noffsinger, Janette L. Rogers, Robert A. Dobie |
---|---|
Rok vydání: | 2002 |
Předmět: |
Hearing aid
medicine.medical_specialty Reverberation Cross-Over Studies business.industry Hearing loss medicine.medical_treatment Audiology Severity of Illness Index Crossover study Clinical trial Speech and Hearing Hearing Aids Double-Blind Method Otorhinolaryngology Rating scale Humans Medicine medicine.symptom business Hearing Disorders Clipper (electronics) Binaural recording |
Zdroj: | Ear and Hearing. 23:301-307 |
ISSN: | 0196-0202 |
Popis: | Objective: Subjective measures of performance were assessed on three different hearing aid circuits as part of a large clinical trial. These measurements included the Profile of Hearing Aid Performance and a subjective ranking of individual preference. Design: A multi-center, double-masked clinical trial of hearing aids was conducted at eight VA Medical Centers. Three hearing aid circuits, a linear peakclipper, a linear compression limiter and a wide dynamic range compressor, were investigated. The experimental design was a three-period, three-treatment crossover design. Subjects (N = 360) were stratified by site and randomized to one of six sequences for the hearing aid circuits. All fittings were binaural and involved a 3-mo trial with each of the three circuits. All subjective measures were administered for unaided and aided conditions at the end of each trial period. Results: While all of the circuits resulted in improved scores on the aided versus the unaided PHAP, there were few conditions in which one circuit outperformed the others. An exception was the aversiveness of sound subscale where the peak clipper frequently scored worse than either the compression limiter or the wide dynamic range compressor. In the subjective ranking scale the compression limiter received more first place rankings than the other two circuits, especially for one subgroup of patients with moderate flat hearing loss. Conclusions: All circuits were perceived as beneficial by these subjects in most situations. The peak clipper scored worse on aversiveness of sound than did the other two circuits for most subjects, while the compression limiter seemed to have a slight advantage in subjective rankings. Most subjects perceived considerable aided benefit in situations involving background noise and reverberation, situations where hearing aid benefit is often questioned. |
Databáze: | OpenAIRE |
Externí odkaz: |