Pitfall of left sided triple‐lumen catheter for continuous renal replacement therapy: A case report
Autor: | Tetsunori Kawase, Shota Kikuta, Satoshi Ishihara, Shinichi Nakayama, Shigenari Matsuyama, Masafumi Suga, Akihiko Inoue, Masafumi Fukushima, Shinichi Ijuin, Daigo Fujiwara |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2020 |
Předmět: |
triple‐lumen catheter
Medicine (General) medicine.medical_specialty medicine.medical_treatment Blood purification Case Report Triple lumen catheter Case Reports 030204 cardiovascular system & hematology innominate vein Left sided 03 medical and health sciences R5-920 0302 clinical medicine Jugular vein Medicine Renal replacement therapy Innominate vein business.industry General Medicine Blood flow blood purification Surgery Catheter 030220 oncology & carcinogenesis business |
Zdroj: | Clinical Case Reports Clinical Case Reports, Vol 9, Iss 1, Pp 105-108 (2021) |
ISSN: | 2050-0904 |
Popis: | We report a case of vascular injury caused by a multi‐lumen catheter for CRRT inserted through left jugular vein. Diagnosis was delayed because CRRT could be continued. Clinicians should be aware of potential vascular complications associated with the wrong placement of multi‐lumen catheters even if blood flow continues without difficulty. In case of wrong placement of the triple‐lumen catheter as a vascular access for CRRT, the blood flow may be maintained, even if a catheter causes vascular injury. The clinician should ensure to place the tip of catheter in the right atrium. |
Databáze: | OpenAIRE |
Externí odkaz: |