A field intercomparison of three passive air samplers for gaseous mercury in ambient air
Autor: | Francesca Sprovieri, Emiliano Zampetti, Carl P. J. Mitchell, Antonella Tassone, Antonella Macagnano, Frank Wania, Ingvar Wängberg, Geoff W. Stupple, Attilio Naccarato, Joshua Avossa, Paolo Papa, Nicola Pirrone, Michelle Nerentorp, Alexandra Steffen, John Munthe, Sacha Moretti, Adam R. Martin, Maria Martino, Diana Babi, Eric M. Prestbo |
---|---|
Rok vydání: | 2021 |
Předmět: |
Atmospheric Science
Accuracy and precision mercury 010504 meteorology & atmospheric sciences Atmospheric mercury Elemental mercury Environmental engineering chemistry.chemical_element 010501 environmental sciences Atmospheric sciences 01 natural sciences Blank Axial diffusion Earthwork. Foundations passive sampling 0105 earth and related environmental sciences Detection limit Gaseous mercury TA715-787 TA170-171 Mercury (element) Ambient air chemistry ambient air Environmental science Field conditions |
Zdroj: | Atmospheric Measurement Techniques, Vol 14, Pp 3657-3672 (2021) Atmos. Meas. Tech. Atmospheric measurement techniques 14 (2021): 3657–3672. doi:10.5194/amt-14-3657-2021 info:cnr-pdr/source/autori:Naccarato, Attilio; Tassone, Antonella; Martino, Maria; Moretti, Sacha; Macagnano, Antonella; Zampetti, Emiliano; Papa, Paolo; Avossa, Joshua; Pirrone, Nicola; Nerentorp, Michelle; Munthe, John; Wängberg, Ingvar; Stupple, Geoff W.; Mitchell, Carl P.J.; Martin, Adam R.; Steffen, Alexandra; Babi, Diana; Prestbo, Eric M.; Sprovieri, Francesca; Wania, Frank/titolo:A field intercomparison of three passive air samplers for gaseous mercury in ambient air/doi:10.5194%2Famt-14-3657-2021/rivista:Atmospheric measurement techniques (Print)/anno:2021/pagina_da:3657/pagina_a:3672/intervallo_pagine:3657–3672/volume:14 |
ISSN: | 1867-8548 |
Popis: | Passive air samplers (PASs), which provide time-averaged concentrations of gaseous mercury over the timescale of weeks to months, are promising for filling a gap in the monitoring of atmospheric mercury worldwide. Their usefulness will depend on their ease of use and robustness under field conditions, their availability and affordability, and most notably, their ability to provide results of acceptable precision and accuracy. Here we describe a comparative evaluation of three PASs with respect to their ability to precisely and accurately record atmospheric background mercury concentrations at sites in both southern Italy and southern Ontario, Canada. The study includes the CNR-PAS with gold nanoparticles as a sorbent, developed by the Italian National Research Council, the IVL-PAS using an activated carbon-coated disk, developed by the Swedish Environmental Research Institute, and the MerPAS® using a sulfur-impregnated activated carbon sorbent, developed at the University of Toronto and commercialized by Tekran. Detection limits are deduced from the variability in the amount of mercury quantified in more than 20 field blank samples for each PAS. Analytical and sampling precision is quantified through 22 triplicate deployments for each PAS, ranging in duration from 2 to 12 weeks. Accuracy and bias are assessed through comparison with gaseous elemental mercury concentrations recorded by Tekran 2537 automated mercury analyzers operating alongside the PASs at both locations. The performance of the PASs was significantly better in Italy, with all of them providing concentrations that are not significantly different from the average concentrations of the Tekran 2537 instruments. In Canada, where weather conditions were much harsher and more variable during the February through April deployment period, there are differences amongst the PASs. At both sites, the MerPAS® is currently the most sensitive, precise, and accurate among the three PASs. A key reason for this is the larger size and the radial configuration of the MerPAS®, which results in lower blank levels relative to the sequestered amounts of mercury when compared to the other two PASs, which rely on axial diffusion geometries. Since blank correction becomes relatively smaller with longer deployments, performance tends to be closer amongst the PASs during deployments of 8 and 12 weeks. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |