Popis: A description of this highly integrated drift chamber system is presented. This high resolution and deadtimeless apparatus achieves excellent performance without channel-by-channel parameter corrections. This approach is suited for very large drift chamber systems since it contains an average of less than one active component per channel. In addition to a description of the system, results from beam tests, and actual use in an experiment are discussed.