Systemic ventricular assist device support in Fontan patients: A report by ACTION
Autor: | N.A. Jaworski, Joseph Philip, Shelby Kutty, Matthew Zinn, Anna Joong, Scott R. Auerbach, Angela Lorts, Jennifer Conway, Chet R. Villa, J R Reichman, Ari Cedars, Matthew J. O'Connor, David M. Peng, David A Danford, Farhan Zafar, David L.S. Morales, David W Bearl, Robert A. Niebler, Shuping Chen, John C. Dykes, Kurt R. Schumacher, Christopher E. Mascio, Christina VanderPluym, David N. Rosenthal |
---|---|
Rok vydání: | 2021 |
Předmět: |
Male
Pulmonary and Respiratory Medicine medicine.medical_specialty Adolescent medicine.medical_treatment Population 030204 cardiovascular system & hematology Fontan Procedure 03 medical and health sciences 0302 clinical medicine Interquartile range Internal medicine medicine Humans Registries cardiovascular diseases Child education Retrospective Studies Heart Failure Heart transplantation Transplantation education.field_of_study business.industry Retrospective cohort study medicine.disease Treatment Outcome medicine.anatomical_structure 030228 respiratory system Ventricle Child Preschool Ventricular assist device Heart failure Cardiology Heart Transplantation Female Surgery Heart-Assist Devices Cardiology and Cardiovascular Medicine business Follow-Up Studies |
Zdroj: | The Journal of Heart and Lung Transplantation. 40:368-376 |
ISSN: | 1053-2498 |
DOI: | 10.1016/j.healun.2021.01.011 |
Popis: | BACKGROUND The size of the Fontan population with end-stage heart failure is growing. In this population, heart transplantation has been the only option. This study sought to investigate the efficacy of ventricular assist device (VAD) support in Fontan patients. METHODS We conducted a retrospective study of Fontan patients in the Advanced Cardiac Therapies Improving Outcomes Network. We evaluated patient characteristics, and the clinical and physiologic outcomes after VAD implantation. RESULTS We identified 45 Fontan patients implanted with VAD. The average age of patients was 10 years (interquartile range: 4.5–18) and 30% were female. The majority had a morphologic right ventricle (69%), moderate or greater ventricular dysfunction (83%), and moderate or greater atrioventricular valve regurgitation (65%). The majority of implants were as a bridge to transplantation (76%), and the majority of patients were Interagency Registry for Mechanically Assisted Circulatory Support Profile 2 (56%). The most commonly employed device was the Medtronic HeartWare HVAD (56%). A total of 13 patients were discharged on device support, and 67% of patients experienced adverse events, the most common of which were neurologic (25%). At 1 year after device implantation, the rate of transplantation was 69.5%, 9.2% of patients continued to be VAD supported, and 21.3% of patients had died. Hemodynamically, VAD was effective in decreasing both Fontan and ventricular end-diastolic pressures in some individuals. CONCLUSIONS VAD is effective in supporting patients with end-stage Fontan failure awaiting heart transplantation. Future research should focus on identifying clinical and physiologic characteristics predictive of a favorable response to VAD support. |
Databáze: | OpenAIRE |
Externí odkaz: |