Effects of the addition of subarachnoid clonidine to the anesthetic solution of sufentanil and hyperbaric or hypobaric bupivacaine for labor analgesia
Autor: | Mônica Maria Siaulys Capel Cardoso, Luiz Marcelo Sá Malbouisson, Mário M. Kondo, Thaís Cristina Tebaldi |
---|---|
Rok vydání: | 2008 |
Předmět: | |
Zdroj: | Revista Brasileira de Anestesiologia v.58 n.6 2008 Revista Brasileira de Anestesiologia Sociedade Brasileira de Anestesiologia (SBA) instacron:SBA Revista Brasileira de Anestesiologia, Volume: 58, Issue: 6, Pages: 593-601, Published: DEC 2008 |
ISSN: | 0034-7094 |
DOI: | 10.1590/s0034-70942008000600004 |
Popis: | JUSTIFICATIVA E OBJETIVOS: Adição de clonidina subaracnóidea (±-agonista) prolonga a ação analgésica da combinação sufentanil e bupivacaína isobárica em analgesia combinada para o trabalho de parto ¹. O objetivo deste estudo foi comparar a qualidade de analgesia e a prevalência de efeitos colaterais após a adição de clonidina subaracnóidea à solução anestésica em gestantes durante trabalho de parto. MÉTODO: Após aprovação da Comissão de Ética, 22 gestantes em trabalho de parto receberam aleatoriamente no espaço subaracnóideo 2,5 mg de bupivacaína hiperbárica 0,5% (grupo CLON/HIPER; n = 11) ou 2,5 mg de bupivacaína isobárica 0,5% (grupo CLON/ISO; n = 11) em associação ao sufentanil 2,5 µg e à clonidina 30 µg. A dor avaliada pela Escala Analógica Visual, a freqüência cardíaca e a pressão arterial média foram estudadas a cada 5 minutos nos primeiros 15 minutos e, a seguir, a cada 15 minutos até o nascimento. Foi avaliada a prevalência de efeitos colaterais (náusea, vômito, prurido e sedação). O estudo foi encerrado no momento em que foi necessária complementação analgésica peridural (dor > 3 cm) ou ao nascimento. A análise estatística foi realizada pelos testes t de Student, Qui-quadrado, Fisher e ANOVA de duas vias para medidas repetidas, considerando como significativo p < 0,05. RESULTADOS: Os grupos CLON/HIPER e CLON/ISO foram semelhantes com relação a dados antropométricos, duração da analgesia (70,9 ± 32,9 vs. 85,4 ± 39,5), freqüência cardíaca, ocorrência de prurido, sedação, náusea e vômitos. No grupo CLON/ISO houve diminuição significativa da pressão arterial média com relação ao grupo CLON/HIPER nos momentos 15, 30 e 45 minutos (p < 0,05). CONCLUSÕES: Nas condições estudadas, a adição de clonidina em baixa dose (30 ¼g), associada ao sufentanil, determinou maior ocorrência de hipotensão quando administrada com soluções isobáricas de anestésico local. Com relação aos demais efeitos colaterais, as soluções hiperbáricas e isobáricas comportam-se de maneira semelhante. BACKGROUND AND OBJECTIVES: The addition of subarachnoid clonidine (α-agonist) prolongs the analgesia produced by the combination of sufentanil and isobaric bupivacaine in combined labor analgesia¹. The objective of this study was to compare the quality of analgesia and the prevalence of side effects after the addition of subarachnoid clonidine to the anesthetic solution in labor analgesia. METHODS: After approval by the Ethics Commission, 22 pregnant women in labor were randomly assigned to the subarachnoid administration of either 2.5 mg of 0.5% hyperbaric bupivacaine (CLON/HYPER Group; n = 11) or 2.5 mg of 0.5% isobaric bupivacaine (CLON/ISO Group; n = 11) associated with 2.5 µg of sufentanil and 30 µg of clonidine. Pain, evaluated by the Visual Analogue Scale, heart rate, and mean arterial pressure were assessed every 5 minutes during the first 15 minutes, and then every 15 minutes afterwards until delivery. The prevalence of side effects (nausea, vomiting, pruritus, and sedation) was evaluated. The study was terminated whenever the patient needed supplemental epidural analgesia (pain > 3) or upon delivery of the fetus. The Student t test, Chi-square test, Fisher exact test, and two-way ANOVA for repeated measurements were used in the statistical analysis and a p < 0.05 was considered significant. RESULTS: Anthropometric data, duration of analgesia (70.9 ± 32.9 vs. 85.4 ± 39.5), heart rate, and the incidence of pruritus, sedation, nausea, and vomiting were similar in both groups. Mean arterial pressure was significantly lower in the CLON/ISO Group than in the CLON/HYPER Group at 15, 30, and 45 minutes (p < 0.05). CONCLUSIONS: Under the conditions of the present study, the association of a small dose of clonidine (30 µg) with sufentanil caused a higher incidence of hypotension when the isobaric solution of the local anesthetic was used. For all other side effects, both hyperbaric and isobaric solutions showed similar behavior. JUSTIFICATIVA Y OBJETIVOS: La adición de la clonidina subaracnoidea (±-agonista), prolonga la acción analgésica de la combinación sufentanil y bupivacaína isobárica en analgesia combinada para el trabajo de parto ¹. El objetivo de este estudio fue comparar la calidad de analgesia y la prevalencia de los efectos colaterales, después de la adición de clonidina subaracnoidea a la solución anestésica en gestantes durante el parto. MÉTODO: Después de la aprobación de la Comisión de Ética, 22 gestantes en trabajo de parto recibieron aleatoriamente en el espacio subaracnoideo 2,5 mg de bupivacaína hiperbárica 0,5% (grupo CLON/HIPER; n = 11) o 2,5 mg de bupivacaína isobárica 0,5% (grupo CLON/ISO; n = 11) en asociación con el sufentanil 2,5 µg y la clonidina 30 µg. El dolor evaluado por la Escala Analógica Visual, la frecuencia cardíaca y la presión arterial promedio, fueron estudiados a cada 5 minutos en los primeros 15 minutos y a continuación, a cada 15 minutos hasta el nacimiento. Fue evaluada la prevalencia de efectos colaterales (náusea, vómito, prurito y sedación). El estudio fue terminado en el momento en que se hizo necesaria la complementación analgésica epidural (dolor > 3 cm) o al nacimiento. El análisis estadístico fue realizado a través de los tests t de Student, Chi-cuadrado, Fisher y ANOVA de dos vías para medidas repetidas, considerando como significativo p < 0,05. RESULTADOS: Los grupos CLON/HIPER y CLON/ISO fueron similares con relación a los datos antropométricos, duración de la analgesia (70,9 ± 32,9 vs. 85,4 ± 39,5), frecuencia cardíaca, incidencia de prurito, sedación, náusea y vómitos. En el grupo CLON/ISO hubo una disminución significativa de la presión arterial promedio con relación al grupo CLON/HIPER en los momentos 15, 30, y 45 minutos (p < 0,05). CONCLUSIONES: En las condiciones estudiadas, la adición de clonidina en baja dosis (30 ¼g), asociada al sufentanil, determinó una mayor incidencia de hipotensión cuando se administró con soluciones isobáricas de anestésico local. Con relación a los demás efectos colaterales, las soluciones hiperbáricas e isobáricas se comportan de manera similar. |
Databáze: | OpenAIRE |
Externí odkaz: |