Popis: | To demonstrate that sewage sludge incineration could be a safe operation if well conducted and that hazardous compounds could also be disposed of without problems in sludge incinerators plants, a research program has been set up by the Italian Water Research Institute on a demonstrative scale plant where a completely circulating fluidised bed furnace and a rotary kiln furnace can operate alternatively. In this paper results of tests performed by a fluidised bed furnace on sewage sludge spiked with highly chlorinated compounds under different operating conditions are presented. A deep investigation on micropollutants formation has been made at different sampling points: before and after bag house filter, and at the chimney. The experimental data show that concentrations of PCDDs+PCDFs (TE) and of PAHs do not strictly depend on the operation of the afterburning chamber and that a complete compliance with the European and Italian standards on the emissions were always achieved even in the most critical conditions investigated. |