Influence of extended depth of focus intraocular lenses on visual field sensitivity

Autor: Katsuyoshi Suzuki, Makoto Hatano, Chiemi Yamashiro, Fumiaki Higashijima, Takuya Yoshimoto, Masaaki Kobayashi, Ryu Takabatake, Manami Ohta, Shinichiro Teranishi, Tomohiko Nagai, Yuka Kobayashi, Kazuhiro Kimura, Makiko Takahashi
Jazyk: angličtina
Rok vydání: 2020
Předmět:
Male
Visual acuity
genetic structures
Eye Diseases
Vision
medicine.medical_treatment
Visual Acuity
Glaucoma
Social Sciences
0302 clinical medicine
Pattern standard deviation
Medical Conditions
Lens Implantation
Intraocular

Medicine and Health Sciences
Psychology
Lenses
Intraocular

Multidisciplinary
Eye Lens
Physics
Ophthalmic Procedures
Cataract Surgery
Middle Aged
Visual field
Intraocular lenses
Physical Sciences
Medicine
Female
Sensory Perception
medicine.symptom
Anatomy
Diffraction
Research Article
medicine.medical_specialty
Science
Ocular Anatomy
Surgical and Invasive Medical Procedures
Contrast Sensitivity
03 medical and health sciences
Ocular System
Ophthalmology
medicine
Humans
Aged
Depth Perception
Extended depth of focus
business.industry
Significant difference
Cognitive Psychology
Biology and Life Sciences
Cataract surgery
medicine.disease
eye diseases
030221 ophthalmology & optometry
Waves
Eyes
Cognitive Science
Perception
sense organs
Visual Fields
business
Head
030217 neurology & neurosurgery
Neuroscience
Zdroj: PLoS ONE
PLoS ONE, Vol 15, Iss 9, p e0237728 (2020)
ISSN: 1932-6203
Popis: PurposeTo investigate the influence of EDOF IOLs, TECNIS Symfony® (Johnson & Johnson Surgical Vision, Inc.), on visual field sensitivity and to compare the IOLs with other kinds of IOLs.MethodsThe subjects included the normal fellow eyes of patients who underwent the Humphrey Field Analyzer (HFA) 30-2 with Swedish Interactive Threshold Algorithm Fast within 6 months after cataract due to glaucoma or suspected glaucoma. Each parameter of HFA was compared among eyes implanted with TENIS Symfony® (EDOF group), diffractive bifocal IOLs (bifocal group), and monofocal IOLs (monofocal group).ResultsThe total of 76 eyes, including 24 eyes in the EDOF group, 26 eyes in the bifocal group, and 26 eyes in the monofocal group, were included in this study. Mean deviation (MD) of HFA was -0.24±0.58 dB in the EDOF group, -1.38±0.58 dB in the bifocal group, and 0.02±0.44 dB in the monofocal group. Foveal threshold (FT) of HFA was 35.8±1.6 dB in the EDOF group, 33.6±1.7 dB in the bifocal group, and 36.6±1.4 dB in the monofocal group. In both MD and FT, there was significant difference between the bifocal group and the others (pConclusionTECNIS Symfony® may have little influence on visual field sensitivity, whereas diffractive bifocal IOLs decrease visual field sensitivity.
Databáze: OpenAIRE