Influence of extended depth of focus intraocular lenses on visual field sensitivity
Autor: | Katsuyoshi Suzuki, Makoto Hatano, Chiemi Yamashiro, Fumiaki Higashijima, Takuya Yoshimoto, Masaaki Kobayashi, Ryu Takabatake, Manami Ohta, Shinichiro Teranishi, Tomohiko Nagai, Yuka Kobayashi, Kazuhiro Kimura, Makiko Takahashi |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2020 |
Předmět: |
Male
Visual acuity genetic structures Eye Diseases Vision medicine.medical_treatment Visual Acuity Glaucoma Social Sciences 0302 clinical medicine Pattern standard deviation Medical Conditions Lens Implantation Intraocular Medicine and Health Sciences Psychology Lenses Intraocular Multidisciplinary Eye Lens Physics Ophthalmic Procedures Cataract Surgery Middle Aged Visual field Intraocular lenses Physical Sciences Medicine Female Sensory Perception medicine.symptom Anatomy Diffraction Research Article medicine.medical_specialty Science Ocular Anatomy Surgical and Invasive Medical Procedures Contrast Sensitivity 03 medical and health sciences Ocular System Ophthalmology medicine Humans Aged Depth Perception Extended depth of focus business.industry Significant difference Cognitive Psychology Biology and Life Sciences Cataract surgery medicine.disease eye diseases 030221 ophthalmology & optometry Waves Eyes Cognitive Science Perception sense organs Visual Fields business Head 030217 neurology & neurosurgery Neuroscience |
Zdroj: | PLoS ONE PLoS ONE, Vol 15, Iss 9, p e0237728 (2020) |
ISSN: | 1932-6203 |
Popis: | PurposeTo investigate the influence of EDOF IOLs, TECNIS Symfony® (Johnson & Johnson Surgical Vision, Inc.), on visual field sensitivity and to compare the IOLs with other kinds of IOLs.MethodsThe subjects included the normal fellow eyes of patients who underwent the Humphrey Field Analyzer (HFA) 30-2 with Swedish Interactive Threshold Algorithm Fast within 6 months after cataract due to glaucoma or suspected glaucoma. Each parameter of HFA was compared among eyes implanted with TENIS Symfony® (EDOF group), diffractive bifocal IOLs (bifocal group), and monofocal IOLs (monofocal group).ResultsThe total of 76 eyes, including 24 eyes in the EDOF group, 26 eyes in the bifocal group, and 26 eyes in the monofocal group, were included in this study. Mean deviation (MD) of HFA was -0.24±0.58 dB in the EDOF group, -1.38±0.58 dB in the bifocal group, and 0.02±0.44 dB in the monofocal group. Foveal threshold (FT) of HFA was 35.8±1.6 dB in the EDOF group, 33.6±1.7 dB in the bifocal group, and 36.6±1.4 dB in the monofocal group. In both MD and FT, there was significant difference between the bifocal group and the others (pConclusionTECNIS Symfony® may have little influence on visual field sensitivity, whereas diffractive bifocal IOLs decrease visual field sensitivity. |
Databáze: | OpenAIRE |
Externí odkaz: |