Two-wire protection of side branches to prevent side branch occlusion during stent implantation for bifurcational lesions
Autor: | Kazuki Okamura, Kazuyuki Ozaki, Hirotaka Oda, Kazuyoshi Takahashi, Tsutomu Miida, Keiichi Tsuchida |
---|---|
Rok vydání: | 2010 |
Předmět: | |
Zdroj: | Cardiovascular Intervention and Therapeutics. 25:112-116 |
ISSN: | 1868-4297 1868-4300 |
DOI: | 10.1007/s12928-009-0010-7 |
Popis: | To prevent side branch occlusion during bifurcational lesion stenting, the placement of a wire in both the main branch and side branch is performed for "side-branch protection". However, this procedure does not always prevent side branch occlusion. A procedure for placing two wires in the side branch, called "two-wire protection of side branches", is considered to be more likely to prevent occlusion compared with one-wire protection of the side branch. We report on three cases in which "two-wire protection of side branches" was effectively performed during the stenting of bifurcational lesions. |
Databáze: | OpenAIRE |
Externí odkaz: |