Preoxygenation with the Mapleson D system requires higher oxygen flows than Mapleson A or circle systems
Autor: | Samar K. Taha, Sahar M. Siddik-Sayyid, Carla M. Dagher, Anis Baraka, Mohamad F. El-Khatib, Jules-Marie A. Chehade |
---|---|
Rok vydání: | 2007 |
Předmět: |
Adult
Male medicine.medical_specialty business.industry Respiration Breathing system chemistry.chemical_element General Medicine Respiration Artificial Oxygen Laryngeal Masks Anesthesiology and Pain Medicine chemistry Anesthesia Anesthesiology Anesthesia Closed-Circuit Tidal Volume medicine Breathing Humans Female Anesthesia Inhalation business Oxygen flow rate |
Zdroj: | Canadian Journal of Anesthesia/Journal canadien d'anesthésie. 54:141-145 |
ISSN: | 1496-8975 0832-610X |
DOI: | 10.1007/bf03022011 |
Popis: | This study investigates the efficacy of preoxygenation with Mapleson A and Mapleson D breathing systems vs the circle system with CO2 absorber.Thirteen healthy volunteers underwent tidal volume breathing for three minutes via facemask using Mapleson A, Mapleson D breathing systems or the circle system with CO2 absorber while breathing 100% O2 at flow rates of 5 L.min-1 and 10 L.min-1. Each volunteer acted as his/her own control by going through each of six preoxygenation protocols in random order. Fractional end-tidal O2 concentration (FETO2) was measured at 30-sec intervals. The results were compared among the three anesthesia systems at the two fresh gas flow rates.At a fresh gas flow rate of 5 L.min-1, the Mapleson A and circle systems achieved F(ETO2) values of 90.8+/-1.4% and 90.0+/-1.1%, respectively, compared with the lower F(ETO2) (81.5+/-6.3%, P0.05), achieved with the Mapleson D system. When breathing O2 at 10 L.min-1, the F(ETO2) values after three minutes were similar with the Mapleson A, circle, and Mapleson D breathing systems (91.8+/-2.3%, 91.2+/-1.7%, 90.6+/-2.7%, respectively).When using the Mapleson A and the circle systems for preoxygenation, an oxygen flow rate of 5 L.min-1 can adequately preoxygenate the patient within three minutes, while an oxygen flow of 10 L.min-1 is required to achieve a similar fractional end-tidal O2 concentration with the Mapleson D system. |
Databáze: | OpenAIRE |