Comparison of Different Techniques for the Determination of Platinized Cytostatic Drugs in Urine Samples
Autor: | Marina Arenas, Julia Martín, Juan Luis Santos, Irene Aparicio, Omar Fernández-Sanfrancisco, Esteban Alonso |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2022 |
Předmět: |
MRM mode
SIM mode Organic Chemistry Pharmaceutical Science cytostatic drugs cisplatin carboplatin oxaliplatin LC-UV(DAD) LC-MS/MS Analytical Chemistry Carboplatin Oxaliplatin LC–MS/MS Chemistry (miscellaneous) Drug Discovery Molecular Medicine Cytostatic drugs Physical and Theoretical Chemistry Cisplatin |
Zdroj: | Molecules; Volume 27; Issue 23; Pages: 8139 |
ISSN: | 1420-3049 |
DOI: | 10.3390/molecules27238139 |
Popis: | Platinum-based cytostatic drugs are one of the most widely used cancer treatments. They are excreted via the urinary tract and can reach the environment through wastewater, posing a risk to human health due to their side effects. Four identification and quantification techniques, including liquid chromatography (LC) separation coupled to (i) a diode array ultraviolet (UV(DAD)) (ii), mass spectrometer in single ion monitoring mode (LC-MS) and (iii) multiple reaction monitoring mode (LC-MS/MS) and (iv) derivatization with diethyldithiocarbamate prior to LC-MS/MS analysis, have been optimized and compared for the multiresidue determination of main platinized cytostatic drugs (cisplatin, carboplatin, and oxaliplatin) in urine samples. Parameters that affect the efficiency of the chromatographic separation and analytical determination of different methods (column, mobile phase, wavelength, precursor ions, fragmentor, and product ions) were optimized. Analytical features, such as matrix effect, sensitivity, precision, selectivity, and linearity, were calculated. In terms of selectivity, the derivatization technique was discarded since it was only applicable to the platinated sum. A high dilution of the sample with LC-UV(DAD) was needed to reduce the matrix effect. Overall, the LC-MS/MS method presented the best analytical features (% RSD = 0.991, or method-detection limits between 0.01-1 mu g mL(-1)). The selected method was applied to the quantification of platinized cytostatic drugs in hospital urine samples from oncologic patients. Spanish Ministerio de Industria, Comercio y Turismo AEI-010500-2021-79 AEI-010500-2021B-92 Spanish Government FPU20/00540 |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |