Stent Graft Sizing for Endovascular Abdominal Aneurysm Repair Using Open Source Image Processing Software

Autor: Jan van Schaik, Hugo T.C. Veger, Hein Putter, Evert J. Waasdorp, Koen E.A. van der Bogt, Joost R. van der Vorst, Eva Knöps
Rok vydání: 2020
Předmět:
Intraclass correlation
Computed Tomography Angiography
medicine.medical_treatment
Aortic Rupture
Clinical Decision-Making
Image processing
030204 cardiovascular system & hematology
Prosthesis Design
Endovascular aneurysm repair
Aortography
030218 nuclear medicine & medical imaging
03 medical and health sciences
Blood Vessel Prosthesis Implantation
0302 clinical medicine
Predictive Value of Tests
medicine.artery
medicine
Humans
Computed tomography angiography
Retrospective Studies
Observer Variation
medicine.diagnostic_test
business.industry
Abdominal aorta
Endovascular Procedures
Stent
Reproducibility of Results
General Medicine
Sizing
Blood Vessel Prosthesis
Open source
Treatment Outcome
Radiographic Image Interpretation
Computer-Assisted

Surgery
Stents
Cardiology and Cardiovascular Medicine
Nuclear medicine
business
Software
Aortic Aneurysm
Abdominal
Zdroj: Annals of Vascular Surgery, 71, 411-418. ELSEVIER SCIENCE INC
ISSN: 1615-5947
Popis: Introduction: An important step to reach a favorable outcome of abdominal endovascular aneurysm repair (EVAR) is preoperative sizing of the stent graft using computed tomography angiography (CTA) images of the abdominal aorta. A variety of costly image processing software options is available to obtain the necessary aortic measurements. A package that can be used for EVAR sizing is OsiriX Lite (R)-an open source, freely downloadable image processing option. This study assesses the concurrent validity of OsiriX Lite (R) when compared with commercially available 3Mensio Vascular (R) and Siemens Syngo.via (R).Methods: CTA scans of 20 patients that underwent EVAR for abdominal aneurysm were selected, 10 elective and 10 ruptured. For each scan, 6 observers determined 20 parameters needed for proper stent graft sizing, 2 using Osirix Lite (R), 3 using 3Mensio Vascular (R), and 1 using Siemens Syngo.via (R). For each parameter, an intraclass correlation coefficient (ICC) and a P-value were calculated. Interrater agreement was interpreted using the Koo and Li Guidelines. Time needed to perform EVAR planning was compared.Results: Overall interrater agreement between the 3 sizing options was found to be either "good" or "moderate" for 16 out of 20 parameters (80%). Time needed to perform EVAR planning was not significantly different for Osirix Lite (R) (568 sec) when compared with 3Mensio Vascular (R) (603 sec) or Siemens Syngo.via (R) (659 sec) with a P-value of 0.88.Conclusions: The authors conclude that Osirix Lite (R) is an accurate and time-effective image processing option for preoperative sizing of an EVAR stent graft when matched to 3Mensio Vascular (R) and Siemens Syngo.via (R).