Computed Tomography Angiography medicine.medical_treatment Aortic Rupture Clinical Decision-Making Image processing 030204 cardiovascular system & hematology Prosthesis Design Endovascular aneurysm repair Aortography 030218 nuclear medicine & medical imaging 03 medical and health sciences Blood Vessel Prosthesis Implantation 0302 clinical medicine Predictive Value of Tests medicine.artery medicine Humans Computed tomography angiography Retrospective Studies Observer Variation medicine.diagnostic_test business.industry Abdominal aorta Endovascular Procedures Stent Reproducibility of Results General Medicine Sizing Blood Vessel Prosthesis Open source Treatment Outcome Radiographic Image Interpretation Computer-Assisted Surgery Stents Cardiology and Cardiovascular Medicine Nuclear medicine business Software Aortic Aneurysm Abdominal |
Zdroj: | Annals of Vascular Surgery, 71, 411-418. ELSEVIER SCIENCE INC |
ISSN: | 1615-5947 |
Popis: | Introduction: An important step to reach a favorable outcome of abdominal endovascular aneurysm repair (EVAR) is preoperative sizing of the stent graft using computed tomography angiography (CTA) images of the abdominal aorta. A variety of costly image processing software options is available to obtain the necessary aortic measurements. A package that can be used for EVAR sizing is OsiriX Lite (R)-an open source, freely downloadable image processing option. This study assesses the concurrent validity of OsiriX Lite (R) when compared with commercially available 3Mensio Vascular (R) and Siemens Syngo.via (R).Methods: CTA scans of 20 patients that underwent EVAR for abdominal aneurysm were selected, 10 elective and 10 ruptured. For each scan, 6 observers determined 20 parameters needed for proper stent graft sizing, 2 using Osirix Lite (R), 3 using 3Mensio Vascular (R), and 1 using Siemens Syngo.via (R). For each parameter, an intraclass correlation coefficient (ICC) and a P-value were calculated. Interrater agreement was interpreted using the Koo and Li Guidelines. Time needed to perform EVAR planning was compared.Results: Overall interrater agreement between the 3 sizing options was found to be either "good" or "moderate" for 16 out of 20 parameters (80%). Time needed to perform EVAR planning was not significantly different for Osirix Lite (R) (568 sec) when compared with 3Mensio Vascular (R) (603 sec) or Siemens Syngo.via (R) (659 sec) with a P-value of 0.88.Conclusions: The authors conclude that Osirix Lite (R) is an accurate and time-effective image processing option for preoperative sizing of an EVAR stent graft when matched to 3Mensio Vascular (R) and Siemens Syngo.via (R). |
Databáze: | OpenAIRE |
Externí odkaz: |