Preliminary Study of the Significance of Reverberation by IVUS Detection for Patients With Severe Calcified Lesions

Autor: Ya-jie Guo, Zhiming Wu, Pei-Na Meng, Wei You, Bi-lin Tao, Hong-li Zhang, Tian Xu, Xiangqi Wu, Fei Ye, Yu-he Zhou, Jia-cong Nong
Rok vydání: 2021
Předmět:
Popis: Objectives―To explore the potential significance of the reverberation of calcification by comparing both intravascular ultrasound (IVUS) and optical coherence tomography (OCT) measurement post manual coregistration.Background―The reverberation phenomenon is often detected by IVUS for severe calcified lesions post rotational atherectomy (RA), which is thought to be due to the glassy and smooth inner surfaces of calcifications. Because of the poor penetration of IVUS, it is impossible to measure the thickness of calcifications, and the relationship between multiple reverberations and the thickness of calcification lesions has not been reported before.Methods―A total of forty-nine patients with severe calcified coronary lesions that were detected by IVUS and OCT simultaneously were enrolled in our retrospective study. If reverberation phenomena were detected by IVUS, intravascular imaging (IVI) data (including distance between the IVUS catheter center and the inner surface of the reverberation signal, the intervals between all adjacent reverberation signals, the number of layers of reverberation in IVUS, and the thickness of the calcification in OCT) were measured at the same position and same direction (each cross-section had 4 mutually perpendicular directions) at 1-mm intervals. If the observational point (direction) had a reverberation signal, it was an effective observational point that would be enrolled in our study; otherwise, it would be regarded as an invalid observational point and excluded from this study. The correlation between each reverberation observational value and OCT data was the primary target in this retrospective study. Results―Four hundred twenty-eight valid observational points were analyzed simultaneously by IVUS and OCT; among them, 300 points had a single layer of reverberation, 83 had double layers of reverberation and 42 had multiple layers (≥3 layers) of reverberation by IVUS detection post-RA. Multivariate logistic regression analysis showed that the number of layers of reverberation by IVUS was significantly related to the thickness of calcifications by OCT at the same point and in the same direction (pConclusions―The number of layers of reverberation signal detected by IVUS is positively correlated with the thickness of calcifications measured by OCT post-RA.
Databáze: OpenAIRE