Impact of a Chromatic Aberration-Correcting Intraocular Lens on Automated Refraction
Autor: | Renato Ambrósio, Karolinne Maia Rocha, Joseana L Ferreira, George O. Waring, Larissa Gouvea, Jorge Haddad |
---|---|
Rok vydání: | 2020 |
Předmět: |
Adult
Male medicine.medical_specialty Corneal Wavefront Aberration Pseudophakia genetic structures medicine.medical_treatment Visual Acuity Intraocular lens Refraction Ocular law.invention 03 medical and health sciences 0302 clinical medicine Lens Implantation Intraocular law Ophthalmology Aberrometry Chromatic aberration Myopia medicine Humans Prospective Studies Dioptre Aged Lenses Intraocular Physics Phacoemulsification Middle Aged Refraction eye diseases Spherical aberration Achromatic lens 030221 ophthalmology & optometry Female Surgery sense organs 030217 neurology & neurosurgery |
Zdroj: | Journal of Refractive Surgery. 36:334-339 |
ISSN: | 1081-597X |
DOI: | 10.3928/1081597x-20200403-01 |
Popis: | PURPOSE: To compare ray-tracing aberrometry, Hartmann-Shack wavefront analysis, automated refraction, and manifest refraction in patients with echelette diffractive intraocular lenses (IOLs) and patients with monofocal IOLs with negative spherical aberration. METHODS: Pseudophakic patients implanted with an echelette diffractive IOL (Tecnis ZXR00; Johnson & Johnson Vision) and a control group consisting of patients implanted with a negative spherical aberration monofocal IOL (Tecnis ZCBOO, Johnson & Johnson Vision) were included in this study. Ray-tracing aberrometry (iTrace; Tracey Technologies Corp.), Hartmann-Shack wavefront analysis (LADARWave; Alcon Laboratories, Inc.), automated refraction (Topcon KR-8800; Topcon Medical Systems, Inc.), and manifest refraction spherical equivalent were performed 1 to 3 months postoperatively. RESULTS: Thirty-two eyes implanted with a ZXR00 IOL and 30 eyes implanted with a ZCBOO IOL were enrolled in this study. The ZXR00 IOL group yielded more myopic results with automated refactions (−0.62 ± 0.41 diopters [D]), Hartmann-Shack wavefront analysis (−0.85 ± 0.40 D), and ray-tracing aberrometry (−0.45 ± 0.64 D), compared to manifest refraction (−0.12 ± 0.44 D) ( P < .001). Hartmann-Shack wavefront analysis showed a statistically significant myopic shift (−0.39 ± 0.47 D) in the ZCBOO group compared to ray-tracing aberrometry, automated refraction, and manifest refraction spherical equivalent (−0.14 ± 0.56, −0.14 ± 0.50, and −0.06 ± 0.44 D, respectively; P < .001). CONCLUSIONS: Manifest refraction techniques unique to echelette technology should be used to avoid over-minus end points. Autorefractors and aberrometers commonly use near-infrared light; thus, myopic results are expected with echelette achromatic technology. [ J Refract Surg . 2020;36(5):334–339.] |
Databáze: | OpenAIRE |
Externí odkaz: |