Shear wave elastography findings in Immunoglobulin A Nephropathy patients: is it more specific and sensitive for interstitial fibrosis or interstitial fibrosis/tubular atrophy?

Autor: Esra Dolarslan, Ahmet Kiykim, Yüksel Balcı, İclal Gürses, Yasemin Yuyucu Karabulut, Serap Demir, Kenan Turgutalp, Simge Bardak, Caner Özer, İlter Helvacı
Přispěvatelé: İÜC, Cerrahpaşa Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümü
Jazyk: angličtina
Rok vydání: 2020
Předmět:
Immunoglobulin A
Adult
Male
Pathology
medicine.medical_specialty
Immunoglobulin A Nephropathy
Tubular atrophy
030232 urology & nephrology
Young’s Elastic Modulus
030204 cardiovascular system & hematology
Interstitial fibrosis
urologic and male genital diseases
Critical Care and Intensive Care Medicine
lcsh:RC870-923
Sensitivity and Specificity
Annual incidence
Young's Elastic Modulus
03 medical and health sciences
0302 clinical medicine
Elastic Modulus
medicine
Humans
Prospective Studies
shear waveelastography
Shear wave elastography
biology
interstitial fibrosis
business.industry
Glomerulonephritis
IGA

General Medicine
Middle Aged
medicine.disease
lcsh:Diseases of the genitourinary system. Urology
Fibrosis
Kidney Tubules
Nephrology
Case-Control Studies
biology.protein
Clinical Study
Elasticity Imaging Techniques
Female
Atrophy
business
Kidney disease
Research Article
Zdroj: Renal Failure
article-version (VoR) Version of Record
Renal Failure, Vol 42, Iss 1, Pp 590-599 (2020)
DOI: 10.1080/0886022X.2020.1779087
Popis: WOS:000544516800001 PubMed ID: 32597278 Background:Prediction of prognosis in Immunoglobulin A Nephropathy (IgAN) and taking appropriate precautions may reduce annual incidence of chronic kidney disease. This may be possible by close follow-up for the development and progression of interstitial fibrosis (IF) or interstitial fibrosis/tubular atrophy (IFTA) in IgAN patients. Aim:To investigate whether Young's elastic modulus (YM) which measured shear wave elastography (SWE) might be used for follow-up of IF or IFTA in IgAN patients. Methods:Prospective study was approved by Human Research Ethics Committee. Group 1 consisted of patients with IgAN. Group 2 consisted of healthy control participants. Young's elastic modulus which is a value of stiffness along with longitudinal stiffness was used to evaluate tissue elasticity. Specificity, sensitivity, positive predictive value (PPV) of YM for the presence of IF and IFTA were evaluated. Results:Group 1 consisted of 30 participants, and group 2 consisted of 32 participants. Sensitivity and specificity of SWE to diagnose presence of IF for YM > 15 kPa were 89% and 90%, respectively. PPV among the ones whom IF was diagnosed by YM >15 kPa was 91%. Sensitivity and specificity of SWE to diagnose presence of IFTA for YM > 15 were 65% and 51%, respectively. PPV among the ones whom IFTA was diagnosed by YM >15 kPa was 78.1%. Conclusions:YM which measured SWE is highly specific and sensitive in the diagnosis of IF, but not for IFTA in IgAN patients. Therefore, progression for IF in IgAN may be followed by SWE.
Databáze: OpenAIRE