Static Field Influences on Transcranial Magnetic Stimulation: Considerations for TMS in the Scanner Environment
Autor: | Gabriela Cantarero, John E. Desmond, Jeffrey M. Yau, Reza Jalinous |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2014 |
Předmět: |
Scanner
Static field Time Factors Field (physics) Acoustics medicine.medical_treatment Biophysics Field strength lcsh:RC321-571 Search coil medicine Humans Interleaved TMS-fMRI lcsh:Neurosciences. Biological psychiatry. Neuropsychiatry Physics Brain Mapping General Neuroscience fMRI Reproducibility of Results Equipment Design Magnetic Resonance Imaging Transcranial Magnetic Stimulation Transcranial magnetic stimulation Concurrent TMS-fMRI Electromagnetic coil Brain stimulation Calibration Neurology (clinical) Artifacts Voltage |
Zdroj: | Brain Stimulation, Vol 7, Iss 3, Pp 388-393 (2014) |
Popis: | Background Transcranial magnetic stimulation (TMS) can be combined with functional magnetic resonance imaging (fMRI) to simultaneously manipulate and monitor human cortical responses. Although tremendous efforts have been directed at characterizing the impact of TMS on image acquisition, the influence of the scanner's static field on the TMS coil has received limited attention. Objective/hypothesis The aim of this study was to characterize the influence of the scanner's static field on TMS. We hypothesized that spatial variations in the static field could account for TMS field variations in the scanner environment. Methods Using an MRI-compatible TMS coil, we estimated TMS field strengths based on TMS-induced voltage changes measured in a search coil. We compared peak field strengths obtained with the TMS coil positioned at different locations (B 0 field vs fringe field) and orientations in the static field. We also measured the scanner's static field to derive a field map to account for TMS field variations. Results TMS field strength scaled depending on coil location and orientation with respect to the static field. Larger TMS field variations were observed in fringe field regions near the gantry as compared to regions inside the bore or further removed from the bore. The scanner's static field also exhibited the greatest spatial variations in fringe field regions near the gantry. Conclusions The scanner's static field influences TMS fields and spatial variations in the static field correlate with TMS field variations. Coil orientation changes in the B0 field did not result in substantial TMS field variations. TMS field variations can be minimized by delivering TMS in the bore or outside of the 0–70 cm region from the bore entrance. |
Databáze: | OpenAIRE |
Externí odkaz: |