Novel Mg-0.5Ca-xMn Biodegradable Alloys Intended for Orthopedic Application: An In Vitro and In Vivo Study
Autor: | Eusebiu-Viorel Sindilar, Maria Butnaru, Bogdan Istrate, Corneliu Munteanu, Stefan-Lucian Burlea, Sorin Aurelian Pasca, Roxana Oana Nastasa, Daniela Maria Vlad, Iuliana Mihai |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
Technology
Materials science Morphology (linguistics) Hydrogen Scanning electron microscope Alloy chemistry.chemical_element engineering.material in vitro analysis Article Corrosion In vivo General Materials Science Microscopy QC120-168.85 QH201-278.5 technology industry and agriculture Mg-Ca-Mn biodegradable alloys Engineering (General). Civil engineering (General) equipment and supplies TK1-9971 chemistry Descriptive and experimental mechanics in vivo analysis engineering Body region Chemical stability Electrical engineering. Electronics. Nuclear engineering TA1-2040 Biomedical engineering |
Zdroj: | Materials Materials, Vol 14, Iss 7262, p 7262 (2021) Materials; Volume 14; Issue 23; Pages: 7262 |
ISSN: | 1996-1944 |
Popis: | Mg-based biodegradable materials, used for medical applications, have been extensively studied in the past decades. The in vitro cytocompatibility study showed that the proliferation and viability (as assessed by quantitative MTT-assay—3-(4,5-dimethyltiazol-2-yl)-2,5-diphenyl tetrazolium bromide) were not negatively affected with time by the addition of Mn as an alloying element. In this sense, it should be put forward that the studied alloys don’t have a cytotoxic effect according to the standard ISO 10993-5, i.e., the level of the cells’ viability (cultured with the studied experimental alloys) attained both after 1 day and 5 days was over 82% (i.e., 82, 43–89, 65%). Furthermore, the fibroblastic cells showed variable morphology (evidenced by fluorescence microscopy) related to the alloy sample’s proximity (i.e., related to the variation on the Ca, Mg, and Mn ionic concentration as a result of alloy degradation). It should be mentioned that the cells presented a polygonal morphology with large cytoplasmic processes in the vicinity of the alloy’s samples, and a bipolar morphology in the remote region of the wells. Moreover, the in vitro results seem to indicate that only 0.5% Mn is sufficient to improve the chemical stability, and thus the cytocompatibility; from this point of view, it could provide some flexibility in choosing the right alloy for a specific medical application, depending on the specific parameters of each alloy, such as its mechanical properties and corrosion resistance. In order to assess the in vivo compatibility of each concentration of alloy, the pieces were implanted in four rats, in two distinct body regions, i.e., the lumbar and thigh. The body’s reaction was followed over time, 60 days, both by general clinical examinations considering macroscopic changes, and by laboratory examinations, which revealed macroscopic and microscopic changes using X-rays, CT(Computed Tomography), histology exams and SEM (Scanning Electron Microscopy). In both anatomical regions, for each of the tested alloys, deformations were observed, i.e., a local reaction of different intensities, starting the day after surgery. The release of hydrogen gas that forms during Mg alloy degradation occurred immediately after implantation in all five of the groups examined, which did not affect the normal functionality of the tissues surrounding the implants. Imaging examinations (radiological and CT) revealed the presence of the alloy and the volume of hydrogen gas in the lumbar and femoral region in varying amounts. The biodegradable alloys in the Mg-Ca-Mn system have great potential to be used in orthopedic applications. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |