Popis: |
Direct observation of the 218Po alpha-peak decay with a microcomputer-controlled alpha-spectrometer yielded a mean half-life value of 3.040 +/- 0.008 min, where the error quoted represents twice the standard deviation of the means from 38 separate decay measurements. The 1912 and 1924 218Po half-life measurements, which provided the 3.05-min value listed in nuclear tables for the past 60 y, are critically reviewed. Two more recent experiments, which yielded longer values of 3.11 min (Van Hise et al. 1982) and 3.093 min (Potapov and Soloshenkov 1986), are also discussed. |