Noninvasive coronary angiography with 16-detector row CT: effect of heart rate
Autor: | Andrik J. Aschoff, Robert Manzke, Florian T. Schmid, Hans-Jürgen Brambs, Heshui Shi, Michael Grass, Leon De Vries, Martin H. K. Hoffmann |
---|---|
Rok vydání: | 2004 |
Předmět: |
Adult
Male medicine.medical_specialty Image quality Image processing Coronary Disease computer.software_genre Coronary Angiography Statistics Nonparametric Electrocardiography Imaging Three-Dimensional Voxel Heart Rate Heart rate Image Processing Computer-Assisted Medicine Humans Radiology Nuclear Medicine and imaging Aged medicine.diagnostic_test Cardiac cycle business.industry Middle Aged Data set Regression Analysis Female Tomography Radiology business Tomography X-Ray Computed computer |
Zdroj: | Radiology. 234(1) |
ISSN: | 0033-8419 |
Popis: | To evaluate the effect of heart rate on the quality of coronary angiograms obtained with 16-detector row computed tomography (CT) by using temporally enhanced three-dimensional (3D) approaches.The local ethics committee approved the study, and informed consent was obtained from all patients. Fifty patients underwent coronary CT angiography (heart rate range, 45-103 beats per minute). Raw data from helical CT and electrocardiography (ECG) were saved in a combined data set. Retrospectively ECG-gated images were reconstructed at preselected phases (50% and 80%) of the cardiac cycle. A 3D voxel-based approach with cardiac phase weighting was used for reconstruction. Testing for correlation between heart rate, cardiac phase reconstruction window, and image quality was performed with Kruskal-Wallis analysis. Image quality (freedom from cardiac motion-related artifacts) was referenced against findings at conventional angiography in a secondary evaluation step. Regression analysis was performed to calculate heart rate thresholds for future beta-blocker application.A significant negative correlation was observed between heart rate and image quality (r = 0.80, P.001). Motion artifact-free images were available for 44 (88%) patients and were achieved consistently at a heart rate of 80 or fewer beats per minute (n = 39). Best image quality was achieved at 75 or fewer beats per minute. Segmental analysis revealed that 97% of arterial segments (diameteror = 1.5 mm according to conventional angiography) were assessable at 80 or fewer beats per minute. Premature ventricular contractions and rate-contained arrhythmia did not impede diagnostic assessment of the coronary arteries in 10 (83%) of the 12 patients affected.Motion-free coronary angiograms can be obtained consistently with 16-detector row CT scanners and adaptive multicyclic reconstruction algorithms in patients with heart rates of less than 80 beats per minute. |
Databáze: | OpenAIRE |
Externí odkaz: |