'Eyes Open – Eyes Closed' EEG/fMRI data set including dedicated 'Carbon Wire Loop' motion detection channels

Autor: Eus J.W. Van Someren, Jennifer R Ramautar, Johan van der Meer, Jöran Lepsien, Ysbrand D. van der Werf, Martin Walter, Harald E. Möller, André Pampel, Lydia Hellrung, Germán Gómez-Herrero, Hermann Hinrichs
Přispěvatelé: Amsterdam Neuroscience - Brain Imaging, Integrative Neurophysiology, Anatomy and neurosciences, Netherlands Institute for Neuroscience (NIN)
Rok vydání: 2016
Předmět:
Zdroj: Data in Brief, Vol 7, Iss, Pp 990-994 (2016)
Data in Brief
Data in brief, 7, 990-994. Elsevier BV
Data in Brief, 7, 990-994. Elsevier BV
van der Meer, J, Pampel, A, van Someren, E, Ramautar, J, van der Werf, Y, Gomez-Herrero, G, Lepsien, J, Hellrung, L, Hinrichs, H, Möller, H & Walter, M 2016, ' "Eyes Open-Eyes Closed" EEG/fMRI data set including dedicated "Carbon Wire Loop" motion detection channels ', Data in Brief, vol. 7, pp. 990-994 . https://doi.org/10.1016/j.dib.2016.03.001
van der Meer, J, Pampel, A, van Someren, E, Ramautar, J, van der Werf, Y, Gomez-Herrero, G, Lepsien, J, Hellrung, L, Hinrichs, H, Möller, H & Walter, M 2016, ' "Eyes Open-Eyes Closed" EEG/fMRI data set including dedicated "Carbon Wire Loop" motion detection channels ', Data in brief, vol. 7, pp. 990-994 . https://doi.org/10.1016/j.dib.2016.03.001
Data in Brief, 7, 990-994. Elsevier B.V.
Data in Brief, 7: 990-994
ISSN: 2352-3409
DOI: 10.1016/j.dib.2016.03.001
Popis: This data set contains electroencephalography (EEG) data as well as simultaneous EEG with functional magnetic resonance imaging (EEG/fMRI) data. During EEG/fMRI, the EEG cap was outfitted with a hardware-based add-on consisting of carbon-wire loops (CWL). These yielded six extra׳CWL׳ signals related to Faraday induction of these loops in the main magnetic field “Measurement and reduction of motion and ballistocardiogram artefacts from simultaneous EEG and fMRI recordings” (Masterton et al., 2007) [1].In this data set, the CWL data make it possible to do a direct regression approach to deal with the BCG and specifically He artifact.The CWL-EEG/fMRI data in this paper has been recorded on two MRI scanners with different Helium pump systems (4 subjects on a 3 T TIM Trio and 4 subjects on a 3T VERIO). Separate EEG/fMRI data sets have been recorded for the helium pump ON as well as the helium pump OFF conditions. The EEG-only data (same subjects) has been recorded for a motion artifact-free reference EEG signal outside of the scanner.This paper also links to an EEGlab “EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis” (Delorme and Makeig, 2004) [2] plugin to perform a CWL regression approach to deal with the He pump artifact, as published in the main paper “Carbon-wire loop based artifact correction outperforms post-processing EEG/fMRI corrections-A validation of a real-time simultaneous EEG/fMRI correction method” (van der Meer et al., 2016) [3]. Keywords: Multimodal imaging, EEG/fMRI, Data acquisition, EEG preprocessing
Databáze: OpenAIRE