The reliability of the angle of deviation measurement from the Photo-Hirschberg tests and Krimsky tests
Autor: | S. Bhurachokviwat, P. Singha, S. Na Phatthalung, S. Chouyjan, Supaporn Tengtrisorn, A. Tungsattayathitthan, N. Rattanalert |
---|---|
Rok vydání: | 2021 |
Předmět: |
Male
Light Cornea Reflexes Medicine and Health Sciences Child Hirschberg test Prism cover test Dioptre Mathematics Multidisciplinary Esotropia Vision Tests Physics Electromagnetic Radiation Ophthalmic Procedures Software Engineering Optical Equipment Child Preschool Physical Sciences Medicine Engineering and Technology Female Anatomy Intermittent exotropia Research Article Biotechnology Adult Computer and Information Sciences Adolescent Science Ocular Anatomy Equipment Surgical and Invasive Medical Procedures Bioengineering Computer Software Ocular System medicine Humans Strabismus business.industry Infant Reproducibility of Results Biology and Life Sciences Prisms medicine.disease Krimsky test Cross-Sectional Studies Eyes Minimum deviation Medical Devices and Equipment Nuclear medicine business Head Neuroscience |
Zdroj: | PLoS ONE PLoS ONE, Vol 16, Iss 12, p e0258744 (2021) |
ISSN: | 1932-6203 |
Popis: | Objective To compare the angle of deviation measured from Photo-Hirschberg testing and Krimsky testing, with that from an alternate prism cover test (APCT) in strabismus patients. Methods A cross-sectional study was conducted in Songklanagarind Hospital, Thailand. Thirty-three strabismus patients were photographed for analysis by Photo-Hirschberg testing using computer software. The corneal light reflex displacement, converted into prism diopter (PD), was compared to the angle of deviation measured with APCT. Twenty-eight strabismus patients were tested with the Krimsky test. Data were analyzed using Pearson correlation and paired t-tests. The study excluded 4 intermittent exotropia cases, 1 intermittent esotropia case and 2 which cases missing data for krimsky test. Results The mean±SD of the deviation angle, measured by APCT with a fixation target at 30 cm and 6 m; were 48.09±16.34PD and 47.82±15.73 PD, respectively. At 1 m, the difference in the angle of deviation measured from APCT and the Photo-Hirschberg test within 10 PD were 58.8% and 63.6%, for ET and XT, respectively. The difference in the angle of deviation measured from APCT and Krimsky tests within 10 PD in ET and XT were 86.7% and 80.0%, respectively. At 4 m, the difference in angle of deviation measured from APCT and Photo-Hirschberg tests within 10 PD in ET and XT were 58.8% and 54.5%, respectively; whereas, the difference in the angle of deviation measured from APCT and Krimsky tests within 10 PD in ET and XT were 80.0% and 70.0%, respectively. Conclusion The reliability of Krimsky test was better than Photo-Hirschberg test for measuring an angle of deviation. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |