Wrist sensor reveals sympathetic hyperactivity and hypoventilation before probable SUDEP
Autor: | Francesco Onorati, Daniel Friedman, Chiara Caborni, Orrin Devinsky, Giulia Regalia, Rosalind W. Picard, Matteo Migliorini |
---|---|
Rok vydání: | 2017 |
Předmět: |
0301 basic medicine
business.industry medicine.medical_treatment education Autopsy Wrist medicine.disease Unexpected death Hypoventilation 03 medical and health sciences Epilepsy 030104 developmental biology 0302 clinical medicine medicine.anatomical_structure Anesthesia medicine media_common.cataloged_instance Neurology (clinical) Cardiopulmonary resuscitation medicine.symptom European union Young adult business 030217 neurology & neurosurgery media_common |
Zdroj: | MIT web domain |
ISSN: | 1526-632X 0028-3878 |
Popis: | We report a probable sudden unexpected death in epilepsy (SUDEP) in a 20-year-old man wearing a smartwatch that recorded wrist motion via 3-axis accelerometer (ACC) and electrodermal activity (EDA). EDA reflects sympathetic activity without parasympathetic antagonism.1 The smartwatch (Empatica [Milan, Italy] Embrace, with CE Medical clearance from the European Union for seizure detection) issued an alert, received by the caregiver at 8:50 am, indicating a probable convulsive seizure. An adult trained in cardiopulmonary resuscitation (CPR) arrived at 9:05 am, found the patient pulseless, prone, face in pillow with mucus in his mouth, and commenced CPR for 15 minutes without recovery. The family declined autopsy. |