Comparison between Micro-Computed Tomography and Cone-Beam Computed Tomography in the Assessment of Bone Quality and a Long-Term Volumetric Study of the Augmented Sinus Grafted with an Albumin Impregnated Allograft
Autor: | Bence Tamás Szabó, György Szabó, Ilona Szmirnova, Kaan Orhan, Márton Kivovics, Csaba Dobó-Nagy, Bálint Trimmel, Orsolya Németh, Dóra Iványi, Eitan Mijiritsky |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2020 |
Předmět: |
Cone beam computed tomography
allograft medicine.medical_treatment lcsh:Medicine 02 engineering and technology Positive correlation Article 03 medical and health sciences 0302 clinical medicine 3-year follow up Biopsy Bone quality medicine Sinus (anatomy) Reduction (orthopedic surgery) medicine.diagnostic_test business.industry Micro computed tomography lcsh:R 030206 dentistry General Medicine 021001 nanoscience & nanotechnology bone quality Implant placement cone-beam computed tomography (cbct) medicine.anatomical_structure microcomputed tomography (micro-ct) volumetric study sinus floor elevation 0210 nano-technology Nuclear medicine business |
Zdroj: | Journal of Clinical Medicine, Vol 9, Iss 2, p 303 (2020) Journal of Clinical Medicine Volume 9 Issue 2 |
ISSN: | 2077-0383 |
Popis: | The purpose of our study was to compare micromorphometric data obtained by cone-beam computed-tomography (CBCT) and microcomputed-tomography (micro-CT) of the augmented sinus and to evaluate the long-term stability of the bone gain achieved using BoneAlbumin. Sinus lifts, and after 6-months, healing bone-biopsy and implant placement were carried out. Specimens were analyzed by micro-CT. A total of 16 samples were collected from nine patients (mean age 54.7 ± 6.5 years). Pre-, postoperative, and 3-year control CBCT-data were registered to determine from where the biopsy samples were harvested. Micromorphometric variables were calculated from the micro-CT- and CBCT-data, and their correlation was determined by Spearman's test. The volume of augmented bone was calculated at the time of implant placement and after 3 years. A positive correlation was found between bone-volume fraction, trabecular-separation, open-, and total-porosity, while a negative correlation was found between trabecular-thickness obtained from CBCT- and micro-CT-data (p < 0.05). Mean volumetric reduction of 39.28% (11.88&ndash 60.02%) was observed. Correlation of CBCT- and micro-CT-data suggested that micromorphometric analysis of CBCT reconstructions of the augmented sinuses provided reliable information on the microarchitecture of augmented bone. CBCT as a modality might be adequate in the analysis of bone quality in the augmented sinus. At the 3-year, control sinus grafts showed volumetric stability. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |