Tear film abnormalities in pseudoexfoliation syndrome and normal healthy participants: A comparative analysis

Autor: Shukrullah Noori, Jaya Kaushik, Sandeep Shankar, P.S. Moulick, Rupali Bose, Alok Sati
Rok vydání: 2020
Předmět:
Zdroj: Med J Armed Forces India
ISSN: 0377-1237
DOI: 10.1016/j.mjafi.2019.01.003
Popis: BACKGROUND: Pseudoexfoliative material is being implicated in causing tear film abnormalities, and the aim of the present study was to prove it and to compare with the normal healthy participants. METHODS: A total of 398 eyes of 200 participants were studied, and two groups were formed. The first, pseudoexfoliation syndrome (PEXS) group, included 198 eyes of 100 patients, and the second, age-matched control group, included 200 eyes of 100 participants. Tear film abnormalities were compared in the two groups by tear meniscus height (TMH), Schirmer test I, Schirmer test II and tear film break-up time (TBUT). RESULTS: On comparing the two groups using independent t-test, a significant difference was found in Schirmer test I, Schirmer test II, and TBUT between the PEXS group (Schirmer test I: 23.98 ± 10.68 mm, Schirmer test II: 17.11 ± 8.78 mm, and TBUT: 9.778 ± 5.54 s) and the age-matched control group (Schirmer test I: 27.08 ± 9.58 mm, Schirmer test II: 19.98 ± 8.48 mm, and TBUT: 13.495 ± 5.65 s) (p = 0.003 [Schirmer test I]; p = 0.001 [Schirmer test II]; and p